Parameter assignment
3.6 Parameter assignment of the DP communication
3.6.4

Equidistant DP cycle TDP

Procedure
When the cyclic component of the DP communication is calculated, the DP master
automatically changes the value for the equidistant DP cycle to the minimum required time.
This change must be undone by re-entering the intended value for the equidistant DP cycle.
Dialog: Continuation
Figure 3-10
58
Dialog box: Options
Tab: Equidistance
Entry field: Equidistant DP cycle = 2,000 ms (example value)
OK (close dialog box: Options)
OK (close dialog box: PROFIBUS properties)
OK (close dialog box: Properties - PROFIBUS interface ADI4 ...)
"Options" dialog box
SIMOTION ADI4 - Analog Drive Interface for 4 Axes
Manual, 05/2009, 6FC5 297-0BA01-0BP6