Siemens SIMOTION ADI4 Manual page 45

Analog drive interface for 4 axes
Hide thumbs Also See for SIMOTION ADI4:
Table of Contents

Advertisement

Encoder type SSI
Encoder parameters:
● Parity
● Resolution
● MsgLength
● Encoding
● Baud rate
SIMOTION ADI4 - Analog Drive Interface for 4 Axes
Manual, 05/2009, 6FC5 297-0BA01-0BP6
Select this check box if the encoder data are to be transmitted from the encoder to the
ADI4 with a parity bit.
Encoder resolution in encoder pulses per encoder revolution
Number of user data bits transmitted by the encoder
The following encoder codes are supported:
– Binary
– Gray
The following baud rates are supported:
– 187.5 Kbits/s
– 375 Kbits/s
– 750 Kbits/s
NOTICE
The following boundary conditions must be taken into account for SSI encoders:
• The baud rate setting must be identical for all SSI encoders. If baud rate settings
are different, the baud rate of the SSI encoder with the highest encoder number is
used.
• In conjunction with ADI4, only absolute encoders (SSI) with "Pine tree" data
output format (TSSI) can be operated.
Parameter assignment
3.5 Function parameters
45