pins to Pins with capacitors list. This is necessary to make Automatic YES! function working
properly. Otherwise Automatic YES! function will "think" the pins are still connected and it will
not allow user to insert new device and start new programming.
Programmer / Selftest
Command executes a selftest of current programmer using AP1 PMI selftest pod, which is
included in standard delivery of programmer.
Recommendations how often run Selftest you can find at Maintenance section.
Programmer / Selftest ISP connector
Command executes a selftest of ISP connector of current programmer using AP1 ISP
connector selftest pod.
AP1 ISP connector selftest pod is necessary to use for testing 20 pins ISP connector of
programmers. AP1 ISP connector selftest pod is available as standard accessory for
DATAMAN 448PRO2AP and DATAMAN 48PRO2AP. The order number: 71-2007.
Sequence for testing 20 pins ISP connector:
 Insert AP1 ISP connector selftest pod into PMI connectors of the programmer.
 Interconnect 20 pins connector of AP1 ISP connector selftest pod with an ISP connector of
the programmer with an ISP cable, included in delivery programmer package. Be sure that
pins are interconnected properly (i.e. 1-1, 2-2... 20-20).
 Run selftest of ISP connector in PG4UW (Programmer / Selftest ISP connector...).
We recommend run this test every 6 months.

Options

The Options menu contains commands that let you view and change various default settings.
Options / General options
General options dialog allows user to control and set variety of PG4UW program options. The
options can be saved to PG4UW configuration file when closing PG4UW application, or
anytime by command Options / Save options.
File options
File options page allows you to set options for erase buffer before loading, auto-reload of
current file and recognition method of file formats for loaded files.
Erase buffer before loading option sets erasing buffer (with desired value) automatically
before loading of data file.
In group When current file is modified by another process can be set mode of reloading of
actually loaded (current) file. There are three choices:
 Prompt before reloading file
 Reload automatically
 Ignore change scanning of current file
There are three situations when file modification is tested:
 switching to the control program from another application
95