Dataman 448PRO2AP User Manual page 135

Hide thumbs Also See for 448PRO2AP:
Table of Contents

Advertisement

Examples:
/prj:c:\myfile.eprj
Load project file with name c:\myfile.eprj.
/loadfile:"c:\filename with spaces.bin"
Load file "c:\filename with spaces.bin" to buffer.
/Program[:switch]
switch 'noquest'
switch 'noanyquest'
Examples:
/Program
/Program:noquest
/Program:noanyquest
/Close
/Close: always
Basic rules for using of executive command line parameters:
 command line parameters are not case sensitive
 command line parameters can be used when first starting of program or when program is
already running
 if program is already running, then any of command line operation is processed only when
program was not busy (no operation was currently executing in program). Program must be
in basic state, i.e. main program window focused, no modal dialogs displayed, no menu
commands opened or executed.
 order of processing command line parameters when using more parameters together is
defined firmly as following:
1. Load project (/Prj:...)
2. Load file (/Load file:...)
3. EPROM/Flash select by ID
4. Program device (/Program[:switch])
5. Close of control program (/Close only together with parameter /Program)
Available command line parameters for starting program PG4UW in demo mode
Demo mode is useful in situations, when no programmer device is available. Demo mode can
be used by clicking button Demo in dialog Find programmer or by command line parameter
/demo. Recommended usage of the parameter is:
pg4uw.exe /demo /<programmer name>
where <programmer name> has to be replaced by name of wished programmer as it is used in
PG4UW control program.
forces start of "Program device" operation automatically when program
is starting, or even if program is already running, also one of following
optional switches can be used:
forces start of device programming without question
forces start of device programming without question and after
operation on device is completed, program doesn't show "Repeat"
operation dialog and goes directly into main program window
this parameter has sense together with /Program parameter only, and
makes program to close automatically after device programming is
finished successfully
this parameter has sense together with /Program parameter only, and
makes program to close automatically after device programming is
finished, no matter if device operation was successful or not.
135
Common notes

Advertisement

Table of Contents
loading

This manual is also suitable for:

48pro2ap

Table of Contents