PG4UW
operation. It's useful when you want to have all supported device operations enabled in one
project (multi-project).
Options "One operation" mode - represents enhanced form of protected mode, where
only one operation from all available is enabled. Provides better certainty, because prevents
operator from executing wrong type of device operation.
By building more projects saved in "One operation" mode using Multi-project Wizard you can
put together also non-standard flow of device operations of control SW (e.g. Program +
Verify + Verify + Verify). Please, see examples of use and differences between operation
modes.
To switch program from Protected mode to Normal mode, use the menu command Options /
Normal mode. The "Password required" dialog appears. User has to enter the same
password as the password entered during switch to Protected mode.
Other way to cancel Protected mode of program is closing of program. Next time the program
starts in Normal (standard) mode (the only exception is case of project loaded by command
line parameter with name of project which was saved in Protected mode).
When Protected mode is active, the software indicates this by label Protected mode in right
top corner of Programmer activity log.
If you search information about another option Require project file unique ID before first
programming, indicated by label (ID) next to project file name in bottom status line of control
program, please take a look at chapter File / Save project.
Protected mode in PG4UWMC
Administrator Mode and Operator Mode in PG4UWMC (former Protected mode)
Program PG4UWMC is set by default to Administrator Mode. It means no operation blocking
for user is applied. But in production, there is suitable to block some menu commands, to
ensure, user does not modify important program settings or configuration. Operator Mode is
used for this purpose.
More information about Operator and Administrator Mode is available in chapter Options /
Switch to Operator Mode (in PG4UWMC).
Program PG4UWMC has Protected mode very similar to program PG4UW. The difference is,
that Protected mode can be activated by menu command but cannot be activated by Project
file. Another difference is that Protected mode settings of PG4UWMC are saved to
configuration .ini file of PG4UWMC while program PG4UWMC is closed. During next start of
application PG4UWMC the recent Protected mode settings obtained from .ini file are used.
There is one menu command - Options / Protected mode - that allows using Protected mode
in application PG4UWMC. After selecting the menu Options / Protected mode, password
dialog appears. User has to enter password twice to confirm the password is correct. After
successful password confirmation program switches to Protected mode.
Protected mode settings are saved to configuration .ini file of PG4UWMC. During next start of
program PG4UWMC the Protected mode settings from .ini file are used.
103