Adjusts pressure plate position towards down by lower servo only. Use this command to level
out pressure plate.
Copy configuration from another ZIF socket actuation unit (<Ctrl+A>)
Configure open and close position of programming module's ZIF socket by another ZIF socket
actuation units in multiprogramming system that are already configured.
Set current position of pressure plate as closed ZIF position (<Ctrl+PageUp>)
Remembers current position of pressure plate as position in what the programming module ZIF
socket is close.
Set current position of pressure plate as opened ZIF position (<Ctrl+PageDown>)
Remembers current position of pressure plate as position in what the programming module's
ZIF socket is open.
Close ZIF socket (<PageUp>)
If current ZIF socket actuation unit is configured, this command moves pressure plate to
position in what programming module's ZIF socket is close.
Open ZIF socket (<PageDown>)
If current ZIF socket actuation unit is configured, this command moves pressure plate to
position in what programming module's ZIF socket is open.
Save configuration of ZIF socket actuation unit (<Ctrl+S>)
Saves configuration of the ZIF socket actuation unit.
Recalibration of ZIF socket actuation unit optical sensors (<Ctrl+X>)
Invokes recalibration of ZIF socket actuation unit's optical sensors. Optical sensors are primary
calibrated during setting open and close positions. This command is used when a recalibration
is needed or requested.
Velocity:
Enables change default velocity of ZIF socket actuation unit's pressure plate. A slow velocity is
set by default, this velocity ensures to achieve projected lifetime of actuation unit's mechanical
parts on nominal load. If requested, it's possible to increase the velocity, but it may reduce
mechanical parts lifetime and limit the actuation force to ZIF socket. There are three preset
levels for actuator velocity:
Slow
Medium
Fast
Reset (<Ctrl+X>)
Resets all settings (not saved yet) to previously saved configuration.
Done
Closes ZIF socket actuation unit configuration dialog (doesn't save setting automatically).
Recommended sequence for replacing the programming module and configuring ZIF
socket actuation unit
 Eject pressure plate from shafts, press button Eject pressure plate from shafts <Delete>.
 Replace/insert the programming module. Inserted module must be fixed by screws!
 Change the adjustable bars on the pressure plate so, that the pressure plate with adjustable
bars will be able make proper pressure to ZIF socket on the programming module and will
not obstruct insert programmed device to ZIF socket.
 Click button Place pressure plate to shafts and automatically configure the ZIF socket
actuation unit (<Insert>) and follow the instruction shown by software. This will
automatically configure the ZIF socket actuation unit for detected programming module.
 Check if the pressure plate can fully open the ZIF socket, use buttons Open ZIF socket
(<PageDown>) and Close ZIF socket (<PageUp>) to open and close the ZIF.
achieves max. lifetime and actuation force, but slower speed
higher speed, but still adequate lifetime and actuation force. It's a
compromise between speed and reliability
high speed, the lifetime and actuation force could be significantly limited.
We don't recommend this setting.