Solenoid coil
VACC-S18-...-K4-...-EX4ME
II 2G Ex emb II T6, T5, T4
II 2D Ex tD A21 IP65 T80 °C, T95 °C, T130 °C
Operating instructions
(Original instructions)
Solenoid coil VACC-S18-...-K4-...-EX4ME
1
Further applicable documents
– Certification documents
– VOFC/VOFD assembly instructions
For all available product documentation è www.festo.com/pk
2
Certified solenoid coils
Voltage
Type
24 V DC/AC
VACC-S18-35-K4-1U-EX4M E
110 V DC/AC
VACC-S18-35-K4-2U-EX4M E
230 V DC/AC
VACC-S18-35-K4-3U-EX4M E
24 V DC/AC
VACC-S18-120-K4-1U-EX4M E
110 V DC/AC
VACC-S18-120-K4-2U-EX4M E
230 V DC/AC
VACC-S18-120-K4-3U-EX4M E
60 DC
VACC-S18-120-K4-27-EX4M E
48 DC
VACC-S18-120-K4-7-EX4M E
24 V DC/AC
VACC-S18-35-K4-1UF-EX4M E
24 V DC/AC
VACC-S18-120-K4-1UF-EX4M E
Fig. 1
3
Function
When switching on the voltage, the solenoid is energised and the valve is actuated.
A built-in bridge rectifier or a built-in varistor limits the switch-off overvoltage.
Festo AG & Co. KG
Ruiter Straße 82
73734 Esslingen
Germany
+49 711 347-0
www.festo.com
8073493
2017-10d
[8073495]
. . . . . . . . . . . . . . . . . . . . . . . . . . .
Part no.
562897
562898
562899
3536527
3536565
3535568
3536569
3536573
570785
3535840
4
Application
• The solenoid coil is intended to be used as an actuator for solenoid valves.
• The solenoid coils can be used in combination with the specified solenoid valves
from Festo in zones 1 and 2 for potentially explosive gas atmospheres and in
zones 21 and 22 for potentially explosive dust atmospheres.
• The suitability of other solenoid valves can only be determined in connection
with the assessment of further components of the subsystem. These must
achieve the same safety level.
Note
Label X: special conditions
• Operate the solenoid coils (except variants -1UF-) only with upstream fuses.
è Technical data and product label
• Protect connecting cables that contain silicone or are not crack-resistant
against mechanical damage.
• Protect the device from all mechanical damage.
• For solenoid coils in direct current design -7- and -27-, the maximum permiss­
ible ripple is 20 %.
Note
When using Festo solenoid valves:
• Operate the solenoid valve only with compressed air or neutral gases.
• The device is not intended to be used with other fluids.
• Always draw in the operating medium outside the potentially explosive area.
• Use only solenoid valves approved for potentially explosive areas.
English
5
Requirements for product use
• Comply with all applicable national and international regulations.
• Installation and commissioning should only be carried out by qualified electrical
specialists.
• Use the device in its original status, without any unauthorised modifications.
The certification is no longer valid if the device is altered in any way by anyone
other than the manufacturer.
6
Commissioning
• Observe the product labelling.
• Operate solenoid coils only with upstream fuses (except variants -1UF-).
• Do not commission the solenoid coil until after mounting.
Warning
The discharge of electrostatically charged parts can lead to ignitable sparks.
• Prevent electrostatic discharge by taking appropriate installation and cleaning
measures.
• Include the device in the system's potential equalisation. The surface coating
of the Festo solenoid valves (VOFD-...) is electrically non-conductive.
• Prevent charge-generating processes that are stronger than manual rubbing
of surfaces.
• Do not mount the housing of the solenoid coils in an area of pneumatically
conveyed dusts (e.g. powder jet).
Note
Escaping exhaust air can swirl up dust and create an explosive dust atmosphere.

Advertisement

loading
Need help?

Need help?

Do you have a question about the VACC-S18-35-K4-1U-EX4ME and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Festo VACC-S18-35-K4-1U-EX4ME

  • Page 1 VACC-S18-…-K4-…-EX4ME • The solenoid coils can be used in combination with the specified solenoid valves from Festo in zones 1 and 2 for potentially explosive gas atmospheres and in II 2G Ex emb II T6, T5, T4 zones 21 and 22 for potentially explosive dust atmospheres.
  • Page 2 Block circuit diagrams Technical data VACC-S18-…-K4-1UF-EX4ME 35-1U 35-2U 35-3U 35-1UF 120-1UF Nominal voltage U V DC/ (–15 % / +10 %) Type of voltage Alternating voltage (50 … 60) DC / undulating voltage Nominal power W/VA Duty cycle 100 % (continuous operation) Degree of protection IP65 / 67 in accordance with FN 942017-2 Overvoltage category...

This manual is also suitable for:

Vacc-s18-35-k4-3u-ex4meVacc-s18-35-k4-2u-ex4meVacc-s18-120-k4-1u-ex4meVacc-s18-120-k4-2u-ex4meVacc-s18-120-k4-27-ex4meVacc-s18-120-k4-3u-ex4me ... Show all