Connecting Elements - Festo VAEM-V-S8EPRS2 Operating Instructions Manual

Valve control module
Hide thumbs Also See for VAEM-V-S8EPRS2:
Table of Contents

Advertisement

Product overview
baudrate [kBd]
9.6
Switching position
Tab. 3 Setting the baud rate
5.2.2

Connecting elements

WARNING!
Risk of injury due to electric shock.
For the electrical power supply with extra-low voltages, use only PELV circuits that guarantee a
reinforced isolation from the mains network.
Observe IEC 60204-1/EN 60204-1.
NOTICE!
Material damage due to incorrect or incomplete installation.
The following conditions must be fulfilled for commissioning:
The system must be fully assembled.
The electrical installation must be complete and checked.
Connection [X1]
The connection [X1] shows the power supply and the trigger input.
Plug pattern
Tab. 4 Pin allocation connection [X1]
Ports [X5] and [X6]
The connections [X5] and [X6] are each provided with a terminal to connect the valves.
Plug pattern
terminal [X5]
8
19.2
Pin
Function
1
Power supply: 24 V DC
2
Power supply: GND
3
Functional earth
4
Trigger input: GND
5
Trigger input: 24 V DC
Pin
Function
1
Connection valve 1
2
3
Connection valve 2
4
57.6
115.2
Festo — VAEM-V-S8EPRS2 — 2020-07

Advertisement

Table of Contents
loading