4.3.17.
Parameters:
Returns:
Description:
CAENVME_API
CAENVME_SetScalerConf(long Handle, short Limit, short AutoReset,
CVIOSources Hit, CVIOSources Gate, CVIOSources Reset).
NPO:
00106/03:V2718.MUTx/11

CAENVME_SetScalerConf

[in] Handle
[in] Limit
[in] AutoReset
[in] Hit
[in] Gate
[in] Reset
An error code about the execution of the function.
The function permits to configure the scaler. Limit range is 0 - 1024
(10 bit). The hit signal source can be: input signal 0 (cvInputSrc0)
or input coincidence (cvCoincidence). The gate signal source can be:
front panel button or software (cvManualSW) or input signal 1
(cvInputSrc1). The reset signal source can be: front panel button or
software (cvManualSW) or input signal 1 (cvInputSrc1).
Filename:
V2718_REV11.DOC
Revision date:
03/07/2018
: The handle that identifies the device.
: The counter limit for the scaler.
: Enable/disable the counter auto reset.
: The source signal for the signal to count (see
CVIOSources enum).
: The source signal for the gate (see CVIOSources
enum).
: The source signal to stop the counter (see
CVIOSources enum).