Document type:
Title:
User's Manual (MUT)
Mod. V2718 VME PCI Optical Link Bridge
4.3.11.
Parameters:
Returns:
Description:
CAENVME_API
CAENVME_MBLTReadCycle(long Handle, unsigned long Address, unsigned char
*Buffer, int Size, CVAddressModifier AM, int *count);
4.3.12.
Parameters:
Returns:
Description:
CAENVME_API
CAENVME_BLTWriteCycle(long Handle, unsigned long Address, unsigned char *Buffer,
int size, CVAddressModifier AM, CVDataWidth DW, int *count);
NPO:
00106/03:V2718.MUTx/11
CAENVME_MBLTReadCycle
[in] Handle
: The handle that identifies the device.
[in] Address
: The VME bus address.
[out] Buffer
: The data read from the VME bus.
[in] Size
: The size of the transfer in bytes.
[in] AM
: The address modifier (see CVAddressModifier enum).
[out] count
: The number of bytes transferred.
An error code about the execution of the function.
The function performs a VME multiplexed block transfer read cycle.
CAENVME_BLTWriteCycle
[in] Handle
: The handle that identifies the device.
[in] Address
: The VME bus address.
[in] Buffer
: The data to be written to the VME bus.
[in] Size
: The size of the transfer in bytes.
[in] AM
: The address modifier (see CVAddressModifier enum).
[in] DW
: The data width (see CVDataWidth enum).
[out] count
: The number of bytes transferred.
An error code about the execution of the function.
The function performs a VME block transfer write cycle.