Query Syntax
MAXimum | DEFault ]
Returned Parameters
Related Commands

[SOURce:]REMote:SENSe

This command is used to select the remote measure state of the electronic
load.
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters

[SOURce:]FUNCtion

These equivalent commands select the input regulation mode of the electronic
load.
CURRent
RESistance
VOLTage
POWer
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters

[SOURce:]FUNCtion:MODE

This command determines whether the input regulation mode is controlled by
values in a list or by the command FUNCtion settings.
FIXed The regulation mode is determined by the FUNCtion or MODE
command.
LIST
Command Syntax
Parameters
*RST Value
Examples
Query Syntax
Returned Parameters
Related Commands

[SOURce:]TRANsient

This command turns the transient generator on or off.
Command Syntax
Parameters
*RST Value
[SOURce:]INPut:TIMer:DELay? [ MINimum |
INP:TIM
[SOURce:]REMote:SENSe[:STATe] <BOOL>
0 | 1 | OFF | ON
0
REM:SENS 0
[SOURce:] REMote:SENSe [:STATe]?
constant current mode
constant resistance mode
constant voltage mode
constant power mode
[SOURce:]FUNCtion <function>
CURRent | RESistance | VOLTage | POWer |
CURRent
FUNC RES
[SOURce:]FUNCtion?
The regulation mode is determined by the active list.
[SOURce:]FUNCtion:MODE <mode>
FIXed | LIST
FIXed
FUNC:MODE FIX
[SOURce:]FUNCtion:MODE?
FUNC
[SOURce:]TRANsient[:STATe] <bool>
0 | 1 | OFF | ON
OFF
Copyright © ITECH Electronic Co., Ltd.