Chapter3 Ieee488.2 Commands - ITech IT8800 Series Programming Manual

Programmable dc electronic load
Hide thumbs Also See for IT8800 Series:
Table of Contents

Advertisement

Common commands begin with an * and consist of three letters (command) or
three letters and a ?(query). They are defined by the IEEE 488.2 standard to
perform common interface functions. Common commands and queries are
categorized under System, Status, or Trigger functions and are listed at the end
of this chapter.
Common Commands
Common commands begin with an * and consist of three letters (command)
IEEE 488.2 standard to perform some common interface functions. The
electronic loads respond to the required common commands that control status
reporting, synchronization, and internal operations. The electronic loads also
respond to optional common commands that control triggers, power-on
conditions, and stored operating parameters.
Common commands and queries are listed alphabetically. If a command has a
corresponding query that simply returns the data or status specified by the
command, then both command and query are included under the explanation
for the command. If a query does not have a corresponding command or is
functionally different from the command, then the query is listed separately. The
description for each common command or query specifies any status registers
affected. Refer to chapter "Programming the Status Registers", which explains
how to read specific register bits and use the information that they return.
Menmonic
*CLS
*ESE
<NRf>
*ESE?
*ESR?
*IDN?
*OPC
*OPC?
*RCL
<NRf>
*RST
*SAV
<NRf>
*SRE
<NRf>
*SRE?
*STB?
*TRG
*TST?
*WAI

Chapter3 IEEE488.2 Commands

Name
Clear status
Event enable command
Event enable query
Event status query
Identification query
Operation complete
command
Operation complete query
Recall Command
Reset Command
Save Command
Service request enable
command
Service request enable
query
Read status byte query
Trigger Command
Self-test query
Wait to continue command
Copyright © ITECH Electronic Co., Ltd.
Description
Clear all event registers and Error Queue
Edit Standard Event Enable Register.
Read Standard Event Enable Register.
Read Standard Event Status Register and clear it
Return the manufacture, model number, serial
number and the firmware revisions of the
instrument.
Set the Operation Complete bit in the Standard
Event Status Register after all pending commands
have been executed.
Places an ASCII "1" into the output queue when all
pending selected device operations have been
completed.
Returns the Load the setup configuration
stored in the specified memory location.
Returned the Load to the *RST default conditions
Saves the current setup to the specified memory
location.
Programs the Service Request Enable register.
Read Service Request Enable register
Read Status Byte Register
Send a trigger to Load.
Performs a self-test and returns the result.
Wait until all previous commands are executed.
IEEE488.2 Commands
19

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents