ITech IT8812B Programming Manual (77 pages)
Programmable DC Electronic Load
Brand:
ITech
| Category:
Control Unit
| Size: 0.94 MB
Table of Contents
Limitation of Warranty
3
Safety Signs
3
Warranty Service
3
Environmental Conditions
4
Safety Precautions
4
Waste Electrical and Electronic Equipment (WEEE) Directive
5
Compliance Information
6
Table of Contents
7
Chapter1 Remote Control
11
Overview
11
SCPI Command Introduction
11
Command Type of SCPI
11
Command Format
13
Data Type
15
Response Data Type
16
Message Type of SCPI
17
SCPI Command Complete
18
Remote Operation
19
Queue
21
Status Byte and Service Request (SRQ)
22
Serial Poll and SRQ
23
Trigger Model (GPIB Operation)
23
Chapter2 SCPI Register
25
Status Register
25
Condition Register
27
Event Register
27
Enable Register
28
Chapter3 IEEE488.2 Commands
29
CLS - Clear Status
30
ESE <Nrf> - Event Enable
30
Esr
30
Idn
30
Opc
31
Psc
31
Rcl
32
Rst
32
Sav
32
Sre
32
Stb
33
Trg
33
Tst
33
Wai
34
Chapter4 Essential Commands
35
Status:questionable
35
Status:questionable:enable
35
Status:questionable:ptransition
35
Status:questionable:ntransition
36
Status:questionable:condition
36
Status:operation
36
Status:operation:enable
36
Status:operation:condition
37
Status:preset
37
Chapter5 System Commands
38
System:preset
38
System:posetup
38
System:version
38
System:error
38
System:clear
39
System:local
39
System:remote
39
System:rwlock
39
System:key
39
Display[:Window]:Mode
40
Display[:Window]:Text
40
Chapter6 Measure Commands
41
Fetch:voltage[:DC]
41
Fetch:voltage:max
41
Fetch:voltage:min
41
Fetch:current[:DC]
42
Fetch:current:max
42
Fetch:current:min
42
Fetch:power[:DC]
43
Fetch:capability
43
Fetch:time
43
Measure:voltage[:DC]
44
Measure:voltage:max
44
Measure:voltage:min
44
Measure:current[:DC]
44
Measure:current:max
45
Measure:current:min
45
Measure:power[:DC]
45
Measure:capability
46
Measure:time
46
Chapter7 Trigger Subsystem
47
Trigger
47
Trigger:source
47
Trigger:timer
47
Chapter8 Trace Subsystem
49
Trace:clear
49
Trace:free
49
Trace:points
49
Trace:feed
49
Trace:feed:control
50
Trace:data
50
Trace:filter
50
Trace:delay
50
Trace:timer
50
Chapter9 Source Subsystem
52
[Source:]Input
52
[Source:]Input:short
52
[Source:]Input:timer
52
[Source:]Input:timer:delay
52
[Source:]Remote:sense
53
[Source:]Function
53
[Source:]Function:mode
53
[Source:]Transient
53
[Source:]Protection:clear
54
[Source:]Current
54
[Source:]Current:range
54
[Source:]Current:slew
55
[Source:]Current:slew:positive
55
[Source:]Current:slew:negative
55
[Source:]Current:slewrate:state
56
[Source:]Current:protection:state
56
[Source:]Current:protection
56
[Source:]Current:protection:delay
56
[Source:]Current:transient:mode
57
[Source:]Current:transient:alevel
57
[Source:]Current:transient:blevel
57
[Source:]Current:transient:awidth
57
[Source:]Current:transient:bwidth
57
[Source:]Current:high
58
[Source:]Current:low
58
[Source:]Voltage
58
[Source:]Voltage:range
58
[Source:]Voltage:range:auto[:State]
59
[Source:]Voltage:on
59
[Source:]Voltage:latch
59
[Source:]Voltage:transient:mode
59
[Source:]Voltage:transient:alevel
60
[Source:]Voltage:transient:blevel
60
[Source:]Voltage:transient:awidth
60
[Source:]Voltage:transient:bwidth
60
[Source:]Voltage:high
61
[Source:]Voltage:low
61
[Source:]Resistance
61
[Source:]Resistance:range
61
[Source:]Resistance:transient:mode
61
[Source:]Resistance:transient:alevel
62
[Source:]Resistance:transient:blevel
62
[Source:]Resistance:transient:0
62
[Source:]Resistance:transient:bwidth
62
[Source:]Resistance:high
63
[Source:]Resistance:low
63
[Source:]Resistance:vdrop
63
[Source:]Resistance:latch[:State]
63
[Source:]Power
63
[Source:]Power:range
64
[Source:]Power:transient:mode
64
[Source:]Power:transient:alevel
64
[Source:]Power:transient:blevel
64
[Source:]Power:transient:awidth
65
[Source:]Power:transient:bwidth
65
[Source:]Power:high
65
[Source:]Power:low
65
[Source:]Power:protection
65
[Source:]Power:protection:delay
66
[Source:]Power:config
66
Chapter10 List Commands
67
[Source:]List:range
67
[Source:]List:count
67
[Source:]List:step
67
[Source:]List:level
67
[Source:]List:slew
68
[Source:]List:width
68
[Source:]List:sav
68
[Source:]List:rcl
68
Chapter11 Sense Subsystem
69
Sense:average:count
69
Sense:time:voltage1
69
Sense:time:voltage2
69
System:sense[:State] <BOOL
69
Chapter12 Calibration Commands
71
Calibrate:secure[:State]
71
Calibrate:initial
71
Calibrate:save
71
Calibrate:current:point
71
Calibrate:current[:Level]
72
Calibrate:current:meter:point
72
Calibrate:current:meter[:Level]
72
Calibrate:voltage:point
72
Calibrate:voltage[:Level]
73
Calibrate:voltage:meter:point
73
Calibrate:voltage:meter[:Level]
73
Chapter13 Error Information
74
Advertisement
ITech IT8812B User Manual (53 pages)
Programmable DC Electronic Load
Brand:
ITech
| Category:
Test Equipment
| Size: 1.02 MB
Table of Contents
Limitation of Warranty
3
Safety Signs
3
Warranty Service
3
Environmental Conditions
4
Safety Precautions
4
Regulation Tag
5
Waste Electrical and Electronic Equipment (WEEE) Directive
5
Compliance Information
6
Table of Contents
7
Chapter1 Acceptance And Installation
9
Confirm Package Contents
9
Installation Position
9
Adjustment of Load Handle
10
Disassembly of Load Handle
11
Installation of Support
11
Connecting the DUT
11
Connecting the Power Line
12
Chapter2 Quick Start
14
Brief Introduction
14
Introduction of Front Board
15
Introduction of Keyboard
15
Fast Function Key
16
Function Description of VFD Status Indicators
16
Introduction of Rear Board
17
Power-On Selftest
17
Chapter3 Function And Features
20
Switching of Local/Remote Operation Modes
20
Constant-Status Operation Mode
20
Constant Current Operation Mode (CC)
20
Constant Voltage Operation Mode (CV)
22
Constant Resistance Operation Mode (CR)
23
Constant Power Operation Mode (CW)
24
Input Control Function
25
Keyboard Locking Function
25
Short-Circuit Analog Function
25
System Menu Function
25
Configuration Menu Function
26
Triggering Function
27
Dynamic Test Function
28
Continuous Mode
28
Pulse Mode
29
Toggle Mode
30
OCP Test Function
32
OPP Test Function
33
Battery Discharge Test Function
34
CR-LED Test Function
35
Measurement of Voltage Rise Time
35
Configuration Save Function
36
VON Function
36
Protective Function
37
Overvoltage Protection (OVP)
37
Overcurrent Protection (OCP)
38
Overpower Protection (OPP)
38
Overtemperature Protection (OTP)
38
List Operation
39
Terminal Function of Rear Board
41
Remote Sense Compensation Functions
41
External Trigger Function
42
External Analog Quantity Test
42
Voltage Fault Indication
42
External On/Off Control
42
Current Monitoring (I Monitor)
42
External Signal Control Interface
43
Auto Test Function
43
Chapter4 Technical Specification
47
Specification
47
Supplementary Characteristic
49
Chapter5 References Of Load Communication Interfaces
50
RS232 Interface
50
USB Interface
51
GPIB Interface
51
Appendix
52
Specifications of Red and Black Test Lines
52
Advertisement
Related Products
ITech IT8812
ITech IT8812C
ITech IT8818B
ITech IT8817C
ITech IT8811
ITech IT8813
ITech IT8814C
ITech IT8816
ITech IT8813B
ITech IT8814
ITech Categories
Power Supply
Test Equipment
Watch
Measuring Instruments
Racks & Stands
More ITech Manuals
Login
Sign In
OR
Sign in with Facebook
Sign in with Google
Upload manual
Upload from disk
Upload from URL