Chapter6 Measure Commands; Fetch:voltage[:Dc]; Fetch:voltage:max; Fetch:voltage:min - ITech IT8800 Series Programming Manual

Programmable dc electronic load
Hide thumbs Also See for IT8800 Series:
Table of Contents

Advertisement

This signal measure command is used to get the read back value. You can use
this high level command to control the measurement process.

FETCh:VOLTage[:DC]?

This command returns the last measured input voltage stored in the
communications buffer of the electronic load. A new measurement is not
initiated by this command.
Group
Syntax
Returns
Example

FETCh:VOLTage:MAX?

This command returns the last measured input maximum voltage stored in the
communications buffer of the electronic load. A new measurement is not
initiated by this command.
Group
Syntax
Returns
Example

FETCh:VOLTage:MIN?

This command returns the last measured input minimum voltage stored in the
communications buffer of the electronic load. A new measurement is not
initiated by this command.
Group
Syntax
Returns

Chapter6 Measure Commands

Measurement
FETCh:VOLTage[:DC]?
<NR2>
FETC:VOLT?
measured voltage across the electronic load inputs in volts.
Measurement
FETCh:VOLTage:MAX?
<NR2>
FETC:VOLT:MAX?
would be the measured maximum voltage across the
electronic load inputs in volts.
Measurement
FETCh:VOLTage:MIN?
<NR2>
Copyright © ITECH Electronic Co., Ltd.
is the measured input voltage in volts.
might return 5.0011, which would be the
is the measured input maximum voltage in volts.
might return 100.0011, which
is the measured input minimum voltage in volts.