2.7 Absolute Maximum Ratings

CHARACTERISTIC DESCRIPTION
Supply Voltage (Absolute Maximum Ratings)
Drain-Source clamp threshold voltage (Absolute
Maximum Ratings),
Digital Input Voltage (Absolute Maximum
Ratings)
Analog Input Voltage (Absolute Maximum
Ratings)

3 CONNECTION, PINOUT, ACCESSORIES

3.1 How to insert SIM card and how to connect battery into FM1200 device :

Open FM1200 case using screwdriver
Insert SIM card as shown
VALUE
I
= 2mA
(
)
drain
Min.
Typ.
-32
-32
-32
Remove FM1200 case
Connect battery connectoras shown
Max.
Unit
32
V
36
V
32
V
32
V