Unknown Network Gsm Operator Code "Vehicle On Stop" Parameters; Min Period (Id=1580); Min Saved Records (Id=1583); Send Period (Id=1584) - Teltonika FM1200 User Manual

Table of Contents

Advertisement

m value
value
0
2592000

8.5.5.2 Min Saved Records (ID=1583)

This parameter defines minimum number of records in one data packet that can be
sent to server. It has higher priority than Data Send Period (ID=1584).
Minimu
Maximu
m value
m value
1
255

8.5.5.3 Send Period (ID=1584)

This parameter indicates frequency (time interval in seconds) of sending data to
server.
Minimu
Maximum
m value
value
0
2592000

8.5.5.4 GPRS Week Time (ID=1585)

Read chapter 8.5.1.4 "GPRS Week Time".

8.5.6 Unknown Network GSM operator code "Vehicle MOVING" parameters

8.5.6.1 Min Period (ID=1590)

This parameter indicates time interval in seconds in order to acquire new record. If
value is 0 it means no records by min period will be saved.
Minimu
Maximum
m value
value
0
2592000

8.5.6.2 Min Distance (ID=1591)

This parameter indicates distance in meters in order to acquire new record. Record
is stored when the distance between previous records is greater than parameter's value.
If value is 0 it means no records by min distance will be saved.
Minimu
Maximu
m value
m value
0
65535
8.5.6.3 Min Angle (ID=1592)
This parameter indicates angle in degrees in order to acquire new record. If angle
difference between last recorded coordinate and current position is greater than defined
value, new record is stored. This parameter is operational, when speed is higher than
10km/h. If value is 0 it means no records by min angle will be saved.
Minimu
Maximu
d value
-
Recommende
Goes with (depends on)
d value
1
GPRS Week Time (ID=1585)
Recommende
Goes with (depends on)
d value
-
GPRS Week Time (ID=1585)
Recommende
Goes with (depends on)
d value
-
GPRS Week Time (ID=1575)
Recommended
Goes with (depends on)
value
-
GPRS Week Time (ID=1575)
Recommende
Goes with (depends on)
parameters
parameters
parameters
Min Saved Records
(ID=1583)
parameters
Min Distance
(ID=1571)
Min Angle (ID=1572)
parameters
Min Period (ID=1570)
Min Angle (ID=1572)
type
U32
Value
type
U8
Value
type
U32
Value
type
U32
Value
type
U32
Value
61