Mitsubishi Electric 800 Series Instruction Manual page 113

Connection
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

 Single-phase 200 V power supply
Model FR-E820S-[]
Applicable
motor
ND
capacity
*1
(kW)
Rated
capacity
ND
*2
(kVA)
Rated
current
ND
*7
(A)
Overload
current
ND
*3
rating
*4
Voltage
Regenera
Brake transistor
tive
Maximum brake torque
braking
Rated input AC voltage/frequency
Permissible AC voltage fluctuation
Permissible frequency fluctuation
Rated
Without DC reactor
input
ND
current
With DC reactor
*8
(A)
Power
Without DC reactor
supply
ND
capacity
With DC reactor
*6
(kVA)
Protective structure (IEC 60529)
Cooling system
Approx. mass (kg)
*1
The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi Electric 4-pole standard efficiency motor.
*2
The rated output capacity is the value with respect to 230 V output voltage.
*3
The percentage of the overload current rating is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow
time for the inverter and motor to return to or below the temperatures under 100% load. For single-phase power input model, the bus voltage
decreases to power failure detection level and the load of 100% or higher may not be available if the automatic restart after instantaneous power
failure function (Pr.57) or the power failure stop function (Pr.261) is set and power supply voltage is low while the load increases.
*4
The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range.
The maximum point of the voltage waveform at the output side of the inverter is approximately the power supply voltage multiplied by
*5
The amount of braking torque is the average short-term torque (which varies depending on motor loss) that is generated when a motor
decelerates in the shortest time by itself from 60 Hz. It is not continuous regenerative torque. The average deceleration torque becomes lower
when a motor decelerates from a frequency higher than the base frequency. The inverter is not equipped with a built-in brake resistor. Use an
option brake resistor for an operation with large regenerative power (not available for the FR-E820S-0008(0.1K) and FR-E820S-0015(0.2K)). The
brake unit (FR-BU2) can be also used.
*6
The power supply capacity varies with the value of the input power impedance (including those of the input reactor and cables).
*7
The value in parentheses is the rated output current when the low acoustic noise operation is performed with the surrounding air temperature
exceeding 40°C while 2 kHz or higher value is selected in Pr.72 PWM frequency selection.
*8
The rated input current is the value at a rated output voltage. The input power impedances (including those of the input reactor and cables) affect
the value.
112
4. Specifications
4.1 Inverter rating
0008
0015
0030
0.1K
0.2K
0.4K
0.75K
0.1
0.2
0.4
0.75
0.3
0.6
1.2
2.0
0.8
1.5
3.0
5.0
(0.8)
(1.4)
(2.5)
(4.1)
150% 60 s, 200% 3 s (inverse-time characteristics) at
surrounding air temperature of 50°C
Three-phase 200 to 240 V
Not used
Built-in
*5
150%
100%
Single-phase 200 to 240 V, 50/60 Hz
170 to 264 V, 50/60 Hz
±5%
2.3
4.1
7.9
11.2
1.4
2.6
5.2
8.7
0.5
0.9
1.7
2.5
0.3
0.6
1.1
1.9
Open type (IP20)
Natural
0.5
0.5
0.8
1.3
0050
0080
0110
1.5K
2.2K
1.5
2.2
3.2
4.4
8.0
11.0
(7.0)
(10.0)
50%
20%
17.9
25.0
13.9
19.1
3.9
5.5
3.0
4.2
Forced air
1.4
1.9
2
.

Advertisement

Table of Contents
loading