Dedicated Motor Outline Dimension Drawings - Mitsubishi Electric 800 Series Instruction Manual

Connection
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

4.4.3

Dedicated motor outline dimension drawings

 Dedicated motor (SF-PR-SC) outline dimension drawings (standard
horizontal type)
Frame number: 90L
Connector (for encoder)
MS3102A20-29P
L
A
KA
B
F
F
N
Frame number: 100L, 112M
Connector (for encoder)
MS3102A20-29P
L
A
R
B
KA
45
XB
F
F
N
Frame number: 132S, 132M
Connector (for encoder)
MS3102A20-29P
L
A
R
KA
B
45
F
F
XB
N
Dimensions table (Unit: mm)
Output (kW)
Frame
4
6
No.
A
B
poles
poles
90L
1.5
230.5 143
100L
2.2
1.5
267
173
100
3.7
256
181
112
112M
2.2
293
181
112
132S
5.5
3.7
270 211.5 132
132M
7.5
5.5
289 230.5 132
NOTE
• The vertical tolerance for the shaft center height is
130
4. Specifications
4.4 Outline dimension drawings
Q
QK
W
XB
S
Section AA
KL
D
60
45
W
J
E
E
M
ML
Section AA
KL
80
D
63
A
A
W
40
E
M
S
ML
Section AA
C
D
E
F
G
H
I
KA
90
184
70
62.5
4
191
53
207
80
70
6.5 203.5 230
65
228
95
70
6.5
226
253
69
228
95
70
6.5
226
253
106
266
108
70
6.5
265
288
75
266
108
70
6.5
265
288
94
KL
D
X
E
E
M
Frame leg viewed
from above
X
Frame leg viewed
from above
X
E
Frame leg viewed
from above
Motor
KL
KG
L
M
ML
N
XB
Q
(KP)
76
158 435.5 175
150 92.5
50
88
169
507
300
212
180
110
60
103
180
506
230
242
180
120
60
103
180
543
230
242
180
120
60
120
197
575
256
268
180
155
80
120
197
613
256
268
180
155
80
 0
.
−0.5
QK
R
S
T
U
W
40
205
24j6
7
4
8
45
240
28j6
7
4
8
45
250
28j6
7
4
8
45
250
28j6
7
4
8
63
305
38j6
8
5
10
63
324
38j6
8
5
10

Hide quick links: