Terminal Connection Diagrams - Mitsubishi Electric 800 Series Instruction Manual

Connection
Hide thumbs Also See for 800 Series:
Table of Contents

Advertisement

2.4

Terminal connection diagrams

 Standard model
Sink logic
Main circuit terminal
Control circuit terminal
Single-phase power input
MCCB
Single-phase
AC power
supply
MCCB
Three-phase
AC power
supply
Control input signals (No voltage input allowed)
Forward
rotation start
Reverse
rotation start
Multi-speed selection
Contact input common
24VDC power supply(Common for
external power supply transistor)
Safety stop input common
Safety stop input (Channel 1)
Safety stop input (Channel 2)
Frequency setting signals (Analog)
Frequency
setting
potentiometer
1/2W1kΩ

Terminal 4 input
(Current input)
Connector for
plug-in option connection
*1
Remove the jumper between P1 and P/+ to connect the DC reactor.
*2
The function of these terminals can be changed using the Input terminal function selection (Pr.178 to Pr.184). (Refer to the FR-E800 Instruction
Manual (Function).)
*3
The initial setting varies depending on the specification.
MC
R/L1
Earth
S/L2
(Ground)
Jumper
MC
R/L1
S/L2
T/L3
Earth
(Ground)

STF
STR
RH
High
speed
RM
Middle
speed
RL
Low
speed
MRS
Output
SOURCE
stop
RES
Reset
SD
PC
S1
Output
S2
shutoff
circuit
Shorting wire
10(+5V)
3
2 0 to 5VDC
2
0 to 10VDC
0 to 20mADC
5(Analog common)
1
(+)
4 4 to 20mADC
(-)
0 to 5VDC
0 to 10VDC
V
Voltage/current
input switch
DC reactor
Brake unit
(FR-HEL)
(Option)

R

PR N/-

P1
P/+
V
W
Main circuit
Control circuit
C
B
A
RUN
FU
SINK
SINK

SE
SOURCE
24V
SO
SOC
PU
Calibration
connector
resistor

USB mini B
FM
connector
SD

2
Output signal: Analog (for the inverter with terminal AM)
I
AM
4
5

Option connector
Motor
M
Earth (Ground)
Relay output 
Relay output
(Fault output)
Open collector output 
Running
Frequency detection
Open collector output common
Sink/source common
Safety stop signal
Safety monitor output
Safety monitor output common
Output signal: Pulse or analog selectable
Output signal: Pulse (for the inverter with terminal FM)
Indicator
+
-
(Frequency meter, etc.)
Moving-coil type
1mA full-scale

(+)
Analog signal output
(0 to ±10VDC)
(-)
2. Installation and Wiring
2.4 Terminal connection diagrams
1
2
3
4
5
6
7
8
9
10
39

Advertisement

Table of Contents
loading

Table of Contents