10.2.4.2.1 Logger Script FW 2.33 (Counter Inputs)

The counter inputs have resulted in counter data and an indicator being added to
the display for non-set time (operating hours) to the logger script ("LV=02.01").
Example:
&HT=1
&LCD2=0;0;e;20F5800;d;0;0;0

10.2.4.2.2 Data Format of an LCDx Variable

Table 44: Data format, logger script extension, Variable LCDx

Index Contents
0
1
2
3
4
5
6
7
The counter status can assume the statuses indicated by the transmitted SMS:

Table 45: Counter status

Status Explanation
0
e
d
o
r
s
c
The counter status shows the last change that has occurred since the last logger
script transmission, or after a system start (independent of the SMS and value
status).
&HT=1: (value always 1) the device time has not been set (&TI entry is operating
hours information, started on 01.01.00 at 00:00:00), otherwise this entry is not
present.
Manual
Version 2.0.0
(same as for Value Script)
Counter status 1st input
Counter value 1st input, hexadecimal Value > 8
Counter status 2nd input
Counter value 2nd input, hexadecimal Value > 8
Counter status 3rd input
Counter value 3rd input, hexadecimal Value > 8
Counter status 4th input
Counter value 4th input, hexadecimal Value > 8
Digital input not configured as a counter.
Counter is active.
Counter is not active.
Counter overflow.
Counter has been reset.
Counter has been started.
Counter value has been changed.
Value Script FW 2.20 (Standard)
Format
Status 1
Status 1
Status 1
Status 1