26
Process Image
4
Process Image
Mapping of process data in the process image of fieldbus systems
The representation of the process data of some I/O modules or their variants in the
process image depends on the fieldbus coupler/controller used. Please take this
information from the section "Fieldbus Specific Design of the Process Data"
included in the description concerning the process image of the corresponding
fieldbus coupler/controller.
Table 16: Output Bits
DO 1
DO 2
DO 3
DO 4
Table 17: Input Bits
DIAG 1
DIAG 2
DIAG 3
DIAG 4
Table 18: Evaluation matrix
Status bit (0...3) wire break/
short circuit
Signal state DO 1 – Digital output channel 1
Signal state DO 2 – Digital output channel 2
Signal state DO 3 – Digital output channel 3
Signal state DO 4 – Digital output channel 4
Diagnostic state DO 1 – Digital output channel 1
Diagnostic state DO 2 – Digital output channel 2
Diagnostic state DO 3 – Digital output channel 3
Diagnostic state DO 4 – Digital output channel 4
Control bit (0 ... 3)
0
0
1
1
750-539 4DO 24V DC VALVE Ex i
Bit 3
Bit 2
DO 4
DO 3
Bit 3
Bit 2
DIAG 4
DIAG 3
Signal status
0
1
0
1
WAGO-I/O-SYSTEM 750
Bit 1
Bit 0
DO 2
DO 1
Bit 1
Bit 0
DIAG 2
DIAG 1
Explanation
Signal status "0"
Signal status "1"
Wire break
Short circuit/overload
Manual