WAGO -I/O-SYSTEM 750-506 Manual
WAGO -I/O-SYSTEM 750-506 Manual

WAGO -I/O-SYSTEM 750-506 Manual

2do 24v dc 0.5a/ diagnostics, 2-channel digital output module 24 vdc, short-circuit, protected; high-side switching; with diagnostics
Hide thumbs Also See for WAGO-I/O-SYSTEM 750-506:
Table of Contents
  • Deutsch

    • Table of Contents
    • 1 Notes about this Documentation

      • Validity of this Documentation
      • Copyright
      • Table 1: Variants
      • Symbols
      • Number Notation
      • Font Conventions
      • Table 2: Number Notation
      • Table 3: Font Conventions
    • 2 Important Notes

      • Legal Bases
      • Subject to Changes
      • Personnel Qualifications
      • Use of the WAGO-I/O-SYSTEM 750 in Compliance with Underlying Provisions
      • Technical Condition of Specified Devices
      • Safety Advice (Precautions)
    • 3 Device Description

      • View
      • Table 4: Legend for Figure "View
      • Connectors
      • Data Contacts/Internal Bus
      • Power Jumper Contacts/Field Supply
      • Table 5: Legend for Figure "Power Jumper Contacts
      • CAGE CLAMP ® Connectors
      • Table 6: Legend for Figure "CAGE CLAMP ® Connectors
      • Display Elements
      • Table 7: Legend for Figure "Display Elements
      • Schematic Diagram
      • Technical Data
      • Device Data
      • Power Supply
      • Communication
      • Outputs
      • Table 8: Technical Data - Device
      • Table 9: Technical Data - Power Supply
      • Table 10: Technical Data - Communication
      • Table 11: Technical Data - Outputs
      • Connection Type
      • Climatic Environmental Conditions
      • Table 12: Technical Data - Field Wiring
      • Table 13: Technical Data - Power Jumper Contacts
      • Table 14: Technical Data - Data Contacts
      • Table 15: Technical Data - Climatic Environmental Conditions
      • Approvals
      • Standards and Guidelines
    • 4 Process Image

      • Table 16: Output Bits
      • Table 17: Input Bits
    • 5 Mounting

      • Mounting Sequence
      • Inserting and Removing Devices
      • Inserting the I/O Module
      • Removing the I/O Module
    • 6 Connect Devices

      • Connecting a Conductor to the CAGE CLAMP
      • Connection Examples
      • 2-Conductor Connection, Ungrounded
      • 2-Conductor Connection, Grounded
      • 3-Conductor Connection, Ungrounded
      • 3-Conductor Connection, Grounded
    • 7 Using Interference-Free Variants of I/O Modules in Safety Related Applications

      • Important Notes
      • Connecting the IO Module to Safety Switching Devices or Safety Modules
      • General Structure
      • Examples of Connection
    • 8 Use in Hazardous Environments

      • Marking Configuration Examples
      • Marking for Europe According to ATEX and IEC-Ex
      • Table 18: Description of Marking Example for Approved I/O Modules According to ATEX and Iecex
      • Table 20: Description of Marking Example for Approved I/O Modules According
      • Table 19: Description of Marking Example for Approved Ex I I/O Modules According to ATEX and Iecex
      • Marking for America According to NEC 500
      • Installation Regulations
      • Special Conditions for Safe Use (ATEX Certificate TÜV 07 ATEX 554086 X)
      • Special Conditions for Safe Use (ATEX Certificate TÜV 12 ATEX 106032 X)
      • Special Conditions for Safe Use (IEC-Ex Certificate TUN 09.0001
      • Special Conditions for Safe Use (IEC-Ex Certificate Iecex TUN 12.0039 X)
      • Special Conditions for Safe Use According to ANSI/ISA
    • Figure 1: View
    • Figure 2: Data Contacts
    • Figure 3: Power Jumper Contacts
    • Figure 4: CAGE CLAMP ® Connectors
    • Figure 5: Display Elements
    • Figure 6: Schematic Diagram
    • Figure 7: Insert I/O Module (Example)
    • Figure 8: Snap the I/O Module into Place (Example)
    • Figure 9: Removing the I/O Module (Example)
    • Figure 10: Connecting a Conductor to a CAGE CLAMP
    • Figure 11: Connecting Diagram, 2-Conductor Connection, Ungrounded
    • Figure 12: Connecting Diagram, 2-Conductor Connection, Grounded
    • Figure 13: Connecting Diagram, 3-Conductor Connection, Ungrounded
    • Figure 14: Connecting Diagram, 3-Conductor Connection, Grounded
    • Figure 15: Potential Group for Safety Related Applications
    • Figure 16: Two-Channel Single-Pole Disconnection
    • Figure 17: Two-Channel Double-Pole Disconnection
    • Figure 18: Side Marking Example for Approved I/O Modules According to ATEX and Iecex
    • Figure 19: Text Detail - Marking Example for Approved I/O Modules According to ATEX and Iecex
    • Figure 20: Side Marking Example for Approved Ex I I/O Modules According to ATEX and Iecex
    • Figure 21: Text Detail - Marking Example for Approved Ex I I/O Modules According to ATEX and Iecex
    • Figure 22: Side Marking Example for I/O Modules According to NEC 500
    • Figure 23: Text Detail - Marking Example for Approved I/O Modules According

Advertisement

Quick Links

Pos : 2 /D okumentati on allgemein/Ei nband/Ei nband H andbuch - Dec kbl att ohne Variantenfel d (Standar d) @ 9\mod_1285229289866_0.doc x @ 64941 @ @ 1
Manual
WAGO-I/O-SYSTEM 750
2DO 24V DC 0.5A/ diagnostics
750-506(/xxx-xxx)
2-Channel Digital Output Module 24 VDC, Short-circuit
Protected; High-side Switching; with Diagnostics
Version 1.2.0
Pos : 3 /Alle Serien (Allgemeine M odul e)/Hinweise z ur Dokumentation/Impres sum für Standardhandbüc her - allg. Angaben, Ansc hriften, Tel efonnummer n und E-Mail-Adres sen @ 3\mod_1219151118203_21.doc x @ 21060 @ @ 1

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the WAGO-I/O-SYSTEM 750-506 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for WAGO WAGO-I/O-SYSTEM 750-506

  • Page 1 Pos : 2 /D okumentati on allgemein/Ei nband/Ei nband H andbuch - Dec kbl att ohne Variantenfel d (Standar d) @ 9\mod_1285229289866_0.doc x @ 64941 @ @ 1 Manual WAGO-I/O-SYSTEM 750 2DO 24V DC 0.5A/ diagnostics 750-506(/xxx-xxx) 2-Channel Digital Output Module 24 VDC, Short-circuit Protected;...
  • Page 2 WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics © 2015 by WAGO Kontakttechnik GmbH & Co. KG All rights reserved. WAGO Kontakttechnik GmbH & Co. KG Hansastraße 27 D-32423 Minden Phone: +49 (0) 571/8 87 – 0 Fax: +49 (0) 571/8 87 – 1 69 E-Mail: info@wago.com...
  • Page 3: Table Of Contents

    2.1.1 Subject to Changes ................9 2.1.2 Personnel Qualifications ............... 9 2.1.3 Use of the WAGO-I/O-SYSTEM 750 in Compliance with Underlying Provisions ..................... 9 2.1.4 Technical Condition of Specified Devices ......... 10 Safety Advice (Precautions) ..............11 Device Description ..................13 View ......................
  • Page 4 Table of Contents WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics Using Interference-Free Variants of I/O Modules in Safety Related Applications ....................33 Important Notes ..................34 Connecting the IO Module to Safety Switching Devices or Safety Modules ....................35 7.2.1...
  • Page 5: Notes About This Documentation

    Pos : 10 /Serie 750 ( WAGO-I/O-SYST EM)/Hi nweis e z ur D okumentati on/Gültigkeits bereic h/Gültig keits ber eich Dokumentation Bus kl emme 750- xxxx, Standar dversi on und aufgelistete Varianten @ 14\mod_1358944038682_21.doc x @ 109354 @ @ 1...
  • Page 6: Symbols

    Notes about this Documentation WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics Pos : 14.3 /All e Seri en ( Allgemei ne Module)/Ü bers chriften für alle Serien/Hinweis e z ur Dokumentation/Symbol e - Ü bersc hrift 2 @ 13\mod_1351068042408_21.doc x @ 105270 @ 2 @ 1 Symbols Pos : 14.4.1 /All e Serien ( Allgemei ne Module)/Wic htige Erläuterungen/Sicherheits- und sons tige Hinweis e/Gefahr/Gefahr: _War nung vor Personenschäden allgemei n_ - Erl äuter ung @ 13\mod_1343309450020_21.doc x @ 101029 @ @ 1...
  • Page 7 WAGO-I/O-SYSTEM 750 Notes about this Documentation 750-506 2DO 24V DC 0.5A/ diagnostics Additional Information: Refers to additional information which is not an integral part of this documentation (e.g., the Internet). Pos : 14.5 /Dokumentation allgemei n/Glieder ungs elemente/---Seitenwechs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1 Manual Version 1.2.0...
  • Page 8: Number Notation

    Font Conventions Table 3: Font Conventions Font Type Indicates italic Names of paths and data files are marked in italic-type. e.g.: C:\Program Files\WAGO Software Menu Menu items are marked in bold letters. e.g.: Save > A greater-than sign between two names means the selection of a menu item from a menu.
  • Page 9: Important Notes

    PLC programming. Pos : 17.5 /Serie 750 (WAGO-I/O-SYST EM)/Wic htige Erläuterungen/Bes timmungsgemäß e Verwendung Bes ti mmungsgemäße Verwendung 750-xxxx - Ü berschrift 3 und Inhal t @ 3\mod_1224064151234_21.doc x @ 24070 @ 3 @ 1 2.1.3...
  • Page 10: Technical Condition Of Specified Devices

    WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics Appropriate housing (per 94/9/EG) is required when operating the WAGO-I/O- SYSTEM 750 in hazardous environments. Please note that a prototype test certificate must be obtained that confirms the correct installation of the system in a housing or switch cabinet.
  • Page 11: Safety Advice (Precautions)

    Pos : 17.10.2 /Serie 750 ( WAGO-I/O- SYST EM)/Wic htig e Erl äuter ung en/Sic her hei ts- und s onstige Hi nweise/Gefahr/Gefahr: Ei nbau 0750- xxxx nur i n Gehäus en, Sc hränken oder el ektrisc hen Betriebsräumen! @ 6\mod_1260180556692_21.doc...
  • Page 12 Important Notes WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics Do not use any contact spray! Do not use any contact spray. The spray may impair contact area functionality in connection with contamination. Pos : 17.11.5 /Alle Serien (Allgemeine D okumente) (Allgemeine M odul e)/Wichtige Erläuter ungen/Sic herheits hinweise/Ac htung/Ac htung: Verpol ung ver mei den! @ 6\mod_1260184045744_21.doc x @ 46767 @ @ 1...
  • Page 13: Device Description

    Pos : 20.2 /Serie 750 (WAGO-I/O-SYST EM)/Ger ätebesc hrei bung/Ei nlei tung/Anwendung/D O/Ü berlast, Kurzsc hlus s und Drahtbruch wer den kanal weise von der Kl emme er kannt. @ 5\mod_1246609628890_21.doc x @ 36550 @ @ 1 These output modules can recognize a short circuit to ground, a line break and an overload in either channel.
  • Page 14 Pos : 20.17 /Serie 750 ( WAGO-I/O-SYST EM)/Wichtig e Erl äuter ung en/Sic her hei ts- und s onstige Hinweise/War nungWarnung: Ei ns atz Variante /xxx- 8xx in sicherheitsg erichteten Anwendung en @ 5\mod_1246882860453_21.doc x @ 36680 @ @ 1...
  • Page 15: View

    Pos : 23 /Serie 750 ( WAGO-I/O-SYST EM)/Ger ätebesc hrei bung/Ansic ht/Digitalausgangs kl emmen/Ansic ht 750-0506 @ 11\mod_1321958026193_21.doc x @ 83472 @ @ 1 Figure 1: View Pos : 24 /Serie 750 ( WAGO-I/O-SYST EM)/Ger ätebesc hrei bung/Ansic ht/Ansic ht C ageCl amp® _Leg ende mit LED s @ 15\mod_1370867188922_21.doc x @ 122225 @ @ 1 Table 4: Legend for Figure “View”...
  • Page 16: Connectors

    Pos : 28.3 /Serie 750 (WAGO-I/O-SYST EM)/Wic htige Erläuterungen/Sicherheits- und sonstig e Hinweis e/Achtung/Achtung: ESD - Auf g ute Erdung der U mgebung ac hten! @ 7\mod_1266318538667_21.doc x @ 50708 @ @ 1 Ensure that the environment is well grounded! The devices are equipped with electronic components that may be destroyed by electrostatic discharge.
  • Page 17: Power Jumper Contacts/Field Supply

    Power Jumper Contacts/Field Supply Pos : 31.1 /Serie 750 (WAGO-I/O-SYST EM)/Wic htige Erläuterungen/Sicherheits- und sonstig e Hinweis e/Vorsic ht/Vorsicht: Verl etz ungsgefahr durc h s charfkantige M ess er kontakte! @ 6\mod_1256193279401_21.doc x @ 43414 @ @ 1 Risk of injury due to sharp-edged blade contacts! The blade contacts are sharp-edged.
  • Page 18 Device Description WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics Do not exceed maximum current via power jumper contacts! The maximum current to flow through the power jumper contacts is 10 A. Greater currents can damage the contacts. When configuring your system, ensure that this current is not exceeded. If exceeded, insert an additional supply module.
  • Page 19: Cage Clamp ® Connectors

    Pos : 34 /Serie 750 ( WAGO-I/O-SYST EM)/Ger ätebesc hrei bung/Ansc hl üss e/Digital ausg angs kl emmen/Anschl üss e 750- 05xx 2 DO 4- Leiter direkt (DO, 24 V, 0 V, Er de) @ 18\mod_1389620358531_21.doc...
  • Page 20: Display Elements

    Display Elements Pos : 37 /Serie 750 ( WAGO-I/O-SYST EM)/Ger ätebesc hrei bung/Anz eigeelemente/Digitalausgangs kl emmen/Anz eigeelemente 750-05xx 2 D O (Ag n, Brt, Cgn, Drt) mit Di ag. @ 18\mod_1389770761299_21.doc x @ 141838 @ @ 1 Figure 5: Display Elements Table 7: Legend for Figure “Display Elements”...
  • Page 21: Schematic Diagram

    Pos : 39 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Gerätebesc hreibung/Sc hematisches Sc haltbil d - Ü bersc hrift 2 @ 4\mod_1240984441312_21.doc x @ 31967 @ 2 @ 1 Schematic Diagram Pos : 40 /Serie 750 ( WAGO-I/O-SYST EM)/Ger ätebesc hrei bung/Schematisc he Sc haltbil der/Digitalausgangs klemmen/Schematisc hes Sc haltbil d 750-0506 @ 11\mod_1321958248035_21.doc x @ 83476 @ @ 1 Figure 6: Schematic Diagram Pos : 41 /D okumentation allgemei n/Glieder ungs elemente/---Seitenwechs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1...
  • Page 22: Technical Data

    Pos : 42 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Gerätebesc hreibung/Technisc he Daten - Ü berschrift 2 @ 3\mod_1232967587687_21.doc x @ 26924 @ 2 @ 1 Technical Data Pos : 43 /Serie 750 ( WAGO-I/O-SYST EM)/Ger ätebesc hrei bung/T echnisc he Daten/Digitalausgangs klemmen/T echnisc he Daten 750- 0506 @ 11\mod_1321960902875_21.doc x @ 83498 @ 3333 @ 1 3.5.1 Device Data Table 8: Technical Data ‒...
  • Page 23: Connection Type

    Pos : 46 /Serie 750 ( WAGO-I/O-SYST EM)/Ger ätebesc hrei bung/T echnisc he Daten/Kli matische U mweltbeding ung en/Technisc he Daten Klimat. U mweltbed. ohne erw. T emp. 0...55°C /-25...+85°C @ 5\mod_1247657968368_21.doc x @ 37603 @ 3 @ 1 3.5.6...
  • Page 24: Approvals

    Pos : 50 /Serie 750 ( WAGO-I/O-SYST EM)/Ger ätebesc hrei bung/Z ulass ungen/Allgemei n/Z ulass ungen Bus kl emme 750- xxxx Allgemein, Standardversi on und all e Vari anten - Einl eitung @ 3\mod_1233911570312_21.doc x @ 27390 @ @ 1...
  • Page 25: Standards And Guidelines

    Standards and Guidelines Pos : 57 /Serie 750 ( WAGO-I/O-SYST EM)/Ger ätebesc hrei bung/N ormen und Ric htlini en/EM V-Nor men Bus kl emme 750- xxxx, ohne Variantenang abe - Einl eitung @ 4\mod_1242803944015_21.doc x @ 33642 @ @ 1...
  • Page 26: Process Image

    Pos : 63 /Serie 750 ( WAGO-I/O-SYST EM)/Proz ess abbild Kl emmenbus /Digitalausg angs kl emmen/Proz ess abbild 750- x5xx 02 DO/D IAG @ 10\mod_1299506283577_21.doc x @ 70540 @ @ 1 Table 16: Output Bits...
  • Page 27: Mounting

    I/O modules with fewer power contacts. Pos : 66.2 /Serie 750 (WAGO-I/O-SYST EM)/Wic htige Erläuterungen/Sicherheits- und sonstig e Hinweis e/Vorsic ht/Vorsicht: Verl etz ungsgefahr durc h s charfkantige M ess er kontakte! @ 6\mod_1256193279401_21.doc x @ 43414 @ @ 1 Risk of injury due to sharp-edged blade contacts! The blade contacts are sharp-edged.
  • Page 28: Inserting And Removing Devices

    WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics Pos : 66.6 /Serie 750 (WAGO-I/O-SYST EM)/M ontieren/D emontieren/Geräte einfüg en und entfer nen - Ü berschrift 2 @ 3\mod_1231768483250_21.doc x @ 25950 @ 2 @ 1 Inserting and Removing Devices Pos : 66.7 /All e Seri en ( Allgemei ne Module)/Wic htige Erläuterungen/Sicherheits- und sons tige Hi nweis e/Ac htung/Achtung: Arbeiten an Ger äten nur s pannungsfr ei durc hführ en! @ 6\mod_1256193963573_21.doc x @ 43426 @ @ 1 Perform work on devices only if they are de-energized! Working on energized devices can damage them.
  • Page 29: Removing The I/O Module

    WAGO-I/O-SYSTEM 750 Mounting 750-506 2DO 24V DC 0.5A/ diagnostics Pos : 66.10 /Serie 750 ( WAGO-I/O-SYST EM)/Monti eren/D emonti eren/Bus kl emme entfer nen @ 4\mod_1239169375203_21.doc x @ 30334 @ 3 @ 1 5.2.2 Removing the I/O Module Remove the I/O module from the assembly by pulling the release tab.
  • Page 30: Connect Devices

    Connect Devices Pos : 69 /Serie 750 ( WAGO-I/O-SYST EM)/Ans chli eßen/Leiter an C AGE C LAM P ans chli eßen ( allgemei n) - Übersc hrift 2 und Text @ 3\mod_1225448660171_21.doc x @ 24928 @ 2 @ 1 ®...
  • Page 31: Connection Examples

    Pos : 71 /All e Seri en (Allgemei ne Module)/Ü berschriften für alle Serien/Ansc hließ en/Ans chl uss beis piel e - Ü berschrift 2 @ 4\mod_1240996036328_21.doc x @ 32010 @ 2 @ 1 Connection Examples Pos : 72 /Serie 750 ( WAGO-I/O-SYST EM)/Ans chli eßen/Anschl uss beispi ele/Digitalausgangs klemmen/Ansc hl ussbeis piel e 750-05xx_2DO_2L_3L_mit Erde @ 18\mod_1389692158254_21.doc x @ 141688 @ 3333 @ 1 6.2.1...
  • Page 32: 3-Conductor Connection, Ungrounded

    Connect Devices WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics 6.2.3 3-Conductor Connection, Ungrounded Figure 13: Connecting Diagram, 3-Conductor Connection, Ungrounded 6.2.4 3-Conductor Connection, Grounded Figure 14: Connecting Diagram, 3-Conductor Connection, Grounded Pos : 73 /D okumentation allgemei n/Glieder ungs elemente/---Seitenwechs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1 Manual Version 1.2.0...
  • Page 33: Using Interference-Free Variants Of I/O Modules In Safety Related Applications

    750-506 2DO 24V DC 0.5A/ diagnostics Pos : 74.1 /Serie 750 (WAGO-I/O-SYST EM)/Eins atz in sicherheitsg erichteten Anwendung en/Ei nleitung - r üc kwir kungsfr eie Varianten @ 6\mod_1258973563064_21.doc x @ 44681 @ 1 @ 1 Using Interference-Free Variants of I/O Modules in Safety Related Applications The variant 750-506/xxx-8xx of the I/O module 750-506 (designation “...
  • Page 34: Important Notes

    750-506 2DO 24V DC 0.5A/ diagnostics Pos : 74.4 /Serie 750 (WAGO-I/O-SYST EM)/Eins atz in sicherheitsg erichteten Anwendung en/Hi nweise zum Ei nsatz i n Sicherheits anwendungen @ 6\mod_1258974811438_21.doc x @ 44688 @ 2 @ 1 Eins atz der rüc kwir kungsfrei en Digital ausg angs kl emme in Sic her heitsanwendungen...
  • Page 35: Connecting The Io Module To Safety Switching Devices Or Safety Modules

    750-506 2DO 24V DC 0.5A/ diagnostics Pos : 74.6 /Serie 750 (WAGO-I/O-SYST EM)/Eins atz in sicherheitsg erichteten Anwendung en/Allgemeiner Aufbau ei ner Potenti algruppe - r üc kwir kungsfr eie Vari anten @ 6\mod_1258973074755_21.doc x @ 44664 @ 23 @ 1...
  • Page 36: Examples Of Connection

    750-506 2DO 24V DC 0.5A/ diagnostics Pos : 76 /Serie 750 ( WAGO-I/O-SYST EM)/Eins atz in sicherheitsg erichteten Anwendung en/Ansc hluss beispi ele/Ansc hlussbeis piel 2/4-Kanal-Digital ausg angs kl emmen i n Sicherheits anwendungen @ 6\mod_1259219930757_21.doc x @ 45290 @ 3 @ 1 Eins atz der rüc kwir kungsfrei en Digital ausg angs kl emme in Sic her heitsanwendungen...
  • Page 37: Figure 17: Two-Channel Double-Pole Disconnection

    WAGO-I/O-SYSTEM 750 Using Interference-Free Variants of I/O Modules in Safety Related Applications 750-506 2DO 24V DC 0.5A/ diagnostics Figure 17: Two-channel Double-pole Disconnection Pos : 77 /D okumentation allgemei n/Glieder ungs elemente/---Seitenwechs el--- @ 3\mod_1221108045078_0.doc x @ 21810 @ @ 1 Manual Version 1.2.0...
  • Page 38: Use In Hazardous Environments

    Use in Hazardous Environments Pos : 78.2 /Serie 750 (WAGO-I/O-SYST EM)/Eins atz in Ex- Ber eichen/Ei ns atz ber eich Serie 750 @ 3\mod_1234272230203_21.doc x @ 27500 @ @ 1 The WAGO-I/O-SYSTEM 750 (electrical equipment) is designed for use in Zone 2 hazardous areas.
  • Page 39: Marking Configuration Examples

    Marking for Europe According to ATEX and IEC-Ex Pos : 78.6 /Serie 750 (WAGO-I/O-SYST EM)/Eins atz in Ex- Ber eichen/Beis piel bedruc kung der ATEX- und IEC- Ex-zug elass enen Bus klemmen gemäß C ENELEC und IEC_2013 @ 14\mod_1360569228625_21.doc x @ 111294 @ @ 1 Figure 18: Side Marking Example for Approved I/O Modules According to ATEX and IECEx Figure 19: Text Detail –...
  • Page 40: Table 18: Description Of Marking Example For Approved I/O Modules According To Atex And Iecex

    Use in Hazardous Environments WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics Table 18: Description of Marking Example for Approved I/O Modules According to ATEX and IECEx Printing on Text Description TÜV 07 ATEX 554086 X Approving authority and certificate numbers IECEx TUN 09.0001 X...
  • Page 41: Figure 20: Side Marking Example For Approved Ex I I/O Modules According To Atex And Iecex

    750-506 2DO 24V DC 0.5A/ diagnostics Pos : 78.8 /Serie 750 (WAGO-I/O-SYST EM)/Eins atz in Ex- Ber eichen/Beis piel bedruc kung der Ex-i- und IEC-Ex-i-zug elas senen Bus klemmen gemäß C ENELEC und IEC _2013 @ 14\mod_1360569320118_21.doc x @ 111298 @ @ 1 Figure 20: Side Marking Example for Approved Ex i I/O Modules According to ATEX and IECEx.
  • Page 42 Use in Hazardous Environments WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics Table 19: Description of Marking Example for Approved Ex i I/O Modules According to ATEX and IECEx Inscription Text Description TÜV 07 ATEX 554086 X Approving authority and certificate numbers IECEx TUN 09.0001X...
  • Page 43: Table 19: Description Of Marking Example For Approved Ex I I/O Modules According To Atex And Iecex

    WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-506 2DO 24V DC 0.5A/ diagnostics Table 19: Description of Marking Example for Approved Ex i I/O Modules According to ATEX and IECEx Gases Equipment group: All except mining 3(1)G Category 3 (Zone 2) equipment containing a safety...
  • Page 44: Marking For America According To Nec 500

    750-506 2DO 24V DC 0.5A/ diagnostics Pos : 78.10 /Serie 750 ( WAGO-I/O-SYST EM)/Ei ns atz i n Ex-Bereic hen/Kennz eichnung für Ameri ka gemäß N EC 500 - Übersc hrift 3 @ 3\mod_1224158423187_21.doc x @ 24188 @ 3 @ 1 8.1.2...
  • Page 45: Installation Regulations

    WAGO-I/O-SYSTEM 750 Use in Hazardous Environments 750-506 2DO 24V DC 0.5A/ diagnostics Pos : 78.13 /Alle Serien (Allgemeine M odul e)/Ei ns atz i n Ex-Bereic hen/Errichtungsbes timmungen - Ü bersc hrift 2 @ 3\mod_1232453624234_21.doc x @ 26370 @ 2 @ 1 Installation Regulations Pos : 78.14 /Alle Serien (Allgemeine M odul e)/Ei ns atz i n Ex-Bereic hen/Errichtungsbes timmungen Ei nleitung_2013 @ 14\mod_1360582328318_21.doc x @ 111371 @ @ 1...
  • Page 46: Special Conditions For Safe Use (Atex Certificate Tüv 07 Atex 554086 X)

    Pos : 78.16 /Serie 750 ( WAGO-I/O-SYST EM)/Ei ns atz i n Ex-Bereic hen/Besonder e Beding ung en für den sic her en Ex- Betrieb gem. AT EX-Z ertifi kat TÜV 07 ATEX 554086_X_2013_2 @ 15\mod_1368620071975_21.doc...
  • Page 47: Special Conditions For Safe Use (Atex Certificate Tüv 12 Atex 106032 X)

    Pos : 78.18 /Serie 750 ( WAGO-I/O-SYST EM)/Ei ns atz i n Ex-Bereic hen/Besonder e Beding ung en für den sic her en Ex- Betrieb gem. AT EX-Z ertifi kat TÜV 12 ATEX 106032x_2013_2 @ 15\mod_1368620479454_21.doc...
  • Page 48: Special Conditions For Safe Use (Iec-Ex Certificate Tun 09.0001

    Pos : 78.20 /Serie 750 ( WAGO-I/O-SYST EM)/Ei ns atz i n Ex-Bereic hen/Besonder e Beding ung en für den sic her en Ex- Betrieb gem. IEC-Ex-Z ertifi kat TUN 09.0001 X_2013_2 @ 15\mod_1368620660911_21.doc...
  • Page 49: Special Conditions For Safe Use (Iec-Ex Certificate Iecex Tun 12.0039 X)

    Pos : 78.22 /Serie 750 ( WAGO-I/O-SYST EM)/Ei ns atz i n Ex-Bereic hen/Besonder e Beding ung en für den sic her en Ex- Betrieb gem. IEC-Ex-Z ertifi kat TUN 12.0039 X_2013_2 @ 15\mod_1368620821493_21.doc...
  • Page 50: Special Conditions For Safe Use According To Ansi/Isa

    WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics Pos : 78.24 /Serie 750 ( WAGO-I/O-SYST EM)/Ei ns atz i n Ex-Bereic hen/Errichtungsbesti mmung en AN SI ISA 12.12.01_2013_2 @ 15\mod_1368620942842_21.doc x @ 119794 @ 3 @ 1 8.2.5 Special Conditions for Safe Use According to ANSI/ISA 12.12.01...
  • Page 51: List Of Figures

    WAGO-I/O-SYSTEM 750 List of Figures 750-506 2DO 24V DC 0.5A/ diagnostics Pos : 80 /D okumentation allgemei n/Verz eic hniss e/Abbil dungs verz eic hnis - Übersc hrift oG und Verz eichnis @ 3\mod_1219222916765_21.doc x @ 21080 @ @ 1 List of Figures Figure 1: View .......................
  • Page 52: List Of Tables

    List of Tables WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics Pos : 82 /D okumentation allgemei n/Verz eic hniss e/Tabell enverz eichnis - Übersc hrift oG und Verz eichnis @ 3\mod_1219222958703_21.doc x @ 21084 @ @ 1 List of Tables Table 1: Variants .....................
  • Page 53 WAGO-I/O-SYSTEM 750 750-506 2DO 24V DC 0.5A/ diagnostics Pos : 84 /D okumentation allgemei n/Einband/Einband H andbuc h - Leers eite für durc h 2 teilbar e Seitenzahl (Standar ddr uc k) @ 3\mod_1219230851078_0.doc x @ 21123 @ @ 1 Manual Version 1.2.0...
  • Page 54 Pos : 85 /D okumentation allgemei n/Einband/Einband H andbuc h - R üc kseite @ 9\mod_1285229376516_21.doc x @ 64944 @ @ 1 WAGO Kontakttechnik GmbH & Co. KG Postfach 2880 • D-32385 Minden Hansastraße 27 • D-32423 Minden Phone: +49/5 71/8 87 – 0 Fax: +49/5 71/8 87 –...

Table of Contents