1. A terminal block is provided inside the top-mounted control
cabinet to provide a 120VAC, 1 AMP Max Load signal.
NOTE:
The Vent Fan Signal Connection supplies 120VAC to a control
relay (supplied by others) when the dishwasher is ON and O
VAC when the dishwasher is OFF. Power to operate the vent
fan (supplied by others) must be supplied separately.
1. Connections are provided for systems that
require a signal to indicate the dishwasher
is running.
2. A signal connection is provided to indicate
that the dishwasher has stopped due to a
conveyor jam or when the clean dish table
is full of racks and additional racks cannot
exit the machine.
3. The table limit switch option is recommended to
be installed on all dishwashers and can be
ordered from the factory P/N 407400.
Machine Running & Table Limit Switch Signal Connections
Vent Fan Signal Connection
SIGNAL ONLY
VENT FAN
120V
COMMON
RINSE AID
120V
COMMON
DETERGENT
120V
SIGNAL ONLY
MACHINE
RUNNING
TABLE
LIMIT
SWITCH
Installation
9