Chemical Connections - Chemical Injection Points - Champion M4.2 Series Installation/Operation Manual With Service Replacement Parts

Undercounter dishwasher
Table of Contents

Advertisement

Installation
Chemical Connections
ALWAYS USE A COMMERCIAL-GRADE NON-CHLORINATED DETERGENT.
PLACE THE CHEMICAL SUPPLY CONTAINERS AS CLOSE TO THE MACHINE AS POSSIBLE.
DO NOT ELEVATE THE CHEMICAL CONTAINERS ABOVE THE FINISHED FLOOR.
Contact a chemical supplier for detergent and rinse-aid chemicals. The chemical supplier must
adjust the chemical dispensing pumps for water hardness and food soil types.
Chemical Dispensing Pumps
1.
The detergent and rinse-aid pumps are located on the lower left-side of the machine
behind the lower-front access panel.
2.
Each pump is equipped with 6 feet [1.8 m] of pick-up tubes consisting of supply tubing,
stiffener tubes, and strainers.
3.
The pick-up tubes are stowed on the back of the machine for shipping.
4.
A red label marked DETERGENT and a blue label marked RINSE-AID identify the
chemical lines.
5.
The chemical squeeze tubes should be inspected and replaced every six months.
The chemical dispensing pumps are located on
the left-side behind the lower front panel
of the dishwasher.
12
! VERY IMPORTANT !
! VERY IMPORTANT !
RINSE-AID
DETERGENT
The chemical dispensing pick-up tubes are
stowed on the back of the dishwasher.