1.
Fuel/Glow Plug Selector Switch - Selects which fuel source
will be used. LPG vs. Gasoline or Diesel for diesel machines.
2.
Auto Leveling Jacks - The leveling jacks switch is located on
the front of the platform control box. When depressed, the
outrigger light will illuminate on the indicator pad. Moving
the control handle forward will lower the leveling jacks.
Moving the control handle backward will raise the leveling
jacks. Once the machine is level, the jacks will discontinue
extending and the jack set light will illuminate.
NOTE:
After initial ground contact is made, the auto level function will
pause 2-5 seconds and then begin to properly level the machine
to the specified market specification. Once level, the tilt light on
the platform control box will stop blinking.
31215865
SECTION 3 - MACHINE CONTROLS AND INDICATORS
NOTE:
There is an override feature on the Auto Leveling system that
allows the operator to adjust (trim) the level of the machine to
the left or right when the platform is completely lowered. Use the
following instructions to adjust the level of the machine.
a. Select the leveling jack selection switch and squeeze
the red trigger switch on the controller.
b. To adjust the leveling jacks to the left, activate the
switch on top of the controller to the left. To adjust to
the right, activate the switch on top of the controller to
the right. The leveling jack indicator light for the side
selected will be lit.