6
Adjusting the settings of the device
Contents
6.1
Setting the target pressure
Pressure setpoint ad‐
justments
Requirements
Setting the target pres‐
sure
User manual for HON R100 gas pressure regulator with HON P095NG pilot
Topic
Setting the target pressure
The following sections show how the gas pressure regulator's operating pressure can be
adjusted with the pilot set screw after commissioning has been completed.
For adjustments during commissioning, please refer to Starting up the gas pressure regulator
(see page 37).
The system is pressurized with the operating pressure.
A pressure gauge is connected in front of the outlet valve.
Proceed as follows:
Figure
Adjusting the settings of the device
Step
Description
1
Unscrew the cap (1).
2
Loosen the lock nut of the set screw (1).
Important! Make sure that the set screw
does not turn as you loosen the nut!
3a
To raise the operating pressure, screw the
set screw in. Adjust the screw position until
the operating pressure you want is
reached.
Page
40