2.2
Device models 
Gas pressure regulator 
versions 
HON R100NG actuator 
assembly models 
HON P095NG pilot mod‐
els 
Versions and designs in 
this user manual 
 
User manual for HON R100 gas pressure regulator with HON P095NG pilot 
Gas pressure regulators consisting of an HON R100NG regulator unit combined with an 
HON P095NG pilot are available in a number of versions. These versions are derived from the 
various possible combinations between the various pilot and actuator assembly versions. 
 
The HON R100NG actuator assembly is available in two designs. In addition to the two basic 
configurations – the standard version and the fail‐open version – an active monitor regulator 
circuit can be set up as well. The table below shows the different characteristics of these 
designs: 
HON R100NG 
Standard version 
fail‐closed 
1", 2", 3", 4", 6", 8" 
nominal inlet sizes 
ANSI class 150 to class 600 pressure ratings 
 
The following table shows which models are available: 
Description 
Design 
Medium‐pressure model 
HON P095NG‐MP 
(medium pressure) 
High‐pressure model 
HON P095NG‐HP 
(high pressure) 
 
The only structural difference between the two versions is the upper diaphragm unit's design, 
meaning that you can switch between the versions by changing the diaphragm unit.   
 
The technical specifications (see page 17) and the Maintenance (see page 44) section, as well 
as the spare parts lists and spare parts drawings in the appendix (see page 81), describe all 
the gas pressure regulator versions and all the models corresponding to the standard for this 
device type. Special‐purpose versions are identified with "SO" in the inspection certificate, 
which is included with the gas pressure regulator. 
The remaining sections in this user manual mostly use the version with the HON P095NG 
pilot as a reference. However, other versions and models will be covered specifically as well 
when there are important differences that need to be pointed out.   
If you have trouble understanding the information in this documentation, contact the manu‐
facturer without fail before starting any work on the device. 
 
HON R100NG‐FO 
 
fail‐open 
1", 2", 3", 4", 6", 8" 
nominal inlet sizes 
ANSI class 150 to class 600 pressure ratings 
 
 
Description 
Setpoint range 
0.5 to 15 bar   
(2.25 to 217 psi) 
10 to 60 bar 
(145 to 860 psi) 