40 
Screw the hex nut (2) and the upper 
diaphragm plate (1) back on the pin (3). 
Use threadlocker as specified in the list in 
the appendix. 
41 
Insert the diaphragm unit (1) back into the 
second pressure stage's housing. 
42 
Put the spring housing back in place, 
Tighten the screws (1), including the 
washers, in a criss‐cross sequence. Refer to 
the additional tightening torque infor‐
mation at the beginning of this topic. 
43 
Insert the compression spring (2) and the 
spring plate (1) back in. 
44 
Take the lock nut. Replace the O‐rings (1, 2) 
with new, lubricated O‐rings. 
 