6.1 Adjusting the regulator unit setpoint
Requirements
Pilot spring of the regulator unit
Specific setpoint
range
W
[mbar]
ds
20 - 30
25 - 50
45 - 75
70 - 100
90 - 160
150 - 200
190 - 260
250 - 300
290 - 360
350 - 400
390 - 500
490 - 560
550 - 660
650 - 760
750 - 800
790 - 900
890 - 1000
HON 380 gas pressure regulator with HON 673/674 controller
Topic
Adjusting the regulator unit setpoint
Adjusting the throttle valve on the measuring line of the regulator unit
Make sure that the following requirements are met:
Apply the inlet pressure slowly because the device is open when in the pres-
sureless state.
The inlet and outlet shut-off devices for the gas regulating line section with
the gas pressure regulator are closed.
The pressure in the outlet chamber downstream of the gas pressure regula-
tor is lower than the setpoint for outlet pressure p
The shut-off devices for the blowdown lines are closed.
The inlet pressure is present upstream of the inlet shut-off device.
RE0
Wire di-
Part no.
ameter
[mm]
Compression spring
RE1
Wire di-
Part no.
ameter
[mm]
10007241
3.6
10003629
4
15055022
4.5
10003630
4.5
15055023
5.3
10003631
5.3
15055024
6.3
10003632
6.3
15055025
7
10003633
7
15055026
7.5
15055027
8.5
15055028
9
15055029
9.5
10012564
9.5
15055030
10
15055031
10
Adjusting the settings of the device
.
d
RE2
Wire di-
Part no.
ameter
[mm]
15056070
5
10009068
6.3
15056072
7
10009069
7
15056073
8
10009070
8
15056074
9
15056075
9
15056076
10
10009072
10
10009073
11
15056077
11
15056078
12
15056079
12
10009164
13
15056081
13
10009165
14
Page
33
36
Color
Signal blue
grey
Gentian blue
Yellow
Fire red
brown
Nut brown
Light red
Rapeseed yel-
low
Dark red
light blue
Rapeseed yel-
low
Cream white
Gentian blue
Emerald green
Fire red
black