Honeywell HON R100NG Series User And Maintenance Manual page 66

Gas pressure regulator with pilot
Table of Contents

Advertisement

Cleaning 
Tightening torques 
Maintaining the 
HON P095NG‐MP pilot 
User manual for HON R100 gas pressure regulator with HON P095NG pilot 
Observe the following cleaning instructions: 
 Before assembly, all parts must be cleaned in order to remove any foreign particles 
(swarf) and soiling. 
 If screws, bolts, or washers are replaced with identical new parts, any oil on these new 
parts must first be removed. 
 
Observe the tightening torques below when following the instructions in this section: 
Part 
Screws 
Screws 
 
Proceed as follows: 
Figure 
Tightening torque 
24 Nm 
47 Nm 
Step 
Description 
Unscrew the cap (1). 
Unscrew the set screw, including the hex 
nut. 
Unscrew the lock nut (1). Remove the lock 
nut. 
Remove the spring plate (1) and the 
compression spring (2). 
 
Maintenance 
Step 
26 
40 
66 