3. Commissioning

3.2

Device master file (GSDML and GSD)

Reference source
3.3

Module identification

Module (order code)
CPX-F8DE-P
1) Module identifier in the operator unit
2) 4 bytes each are used exclusively for PROFIsafe communications
Tab. 3/2:
Module identifier of the input module CPX-F8DE-P
3-4
In conjunction with the input module CPX-F8DE-P, you will
need a current GSDML/GSD device master file for
configuration and programming.
current versions of the GSDML/GSD files for CPX terminals
are available on the Festo website è www.festo.com/sp.
After importing the GSDML/GSD file into the project of the
F-host configuration program, you can select and edit the
CPX terminal with the input module CPX-F8DE-P in the
configuration program.
The configuration, parameterisation and commissioning of
the CPX terminal with CPX-F8DE-P depend on the control
system.
Detailed information can be found in the documentation for
the control system and the online help of the configuration
program.
Each module has a separate identifier (module identifier).
Import the module identifiers – as in the CPX terminal
arranged from left to right – into your configuration
program.
Module identifier
F8DI-P
1)
Assigned I/O bytes
6 bytes I + 7 bytes O
Festo CPX-F8DE-P-EN en 2005b English
2)

Advertisement