4. FUNCTION SETTINGS
No.
Setting range
582
ON/OFF
-150 − 150
583
(degrees)
-110 − 40
584
(degrees)
0 − 500
585
587
0 − 300
0 − 50
588
(ms)
0 − 50
589
(ms)
590
5 − 10
0 − 300
591
(degrees)
200 − 700
592
(sti/min)
0 − 15
593
(ms)
-160 − 20
594
(degrees)
Error processing settings (600 − 699)
No.
Setting range
650
0 − 2
*1
*2
651
ON/OFF
*2
652
ON/OFF
*2
654
ON/OFF
*2
655
ON/OFF
OFF, 2 − 30
657
(seconds)
*1: This is not initialized during initialization mode.
*2: These functions can be used if the main PCB version is 1.5.00 or later.
20
Initial value
Setting units
ON
1
0
5
0
5
470
1
0
1
35
1
20
1
5
1
430F: 270
5
438F: 260
600
100
8
1
0
5
Initial
Setting units
value
0
1
OFF
-
OFF
-
OFF
-
OFF
-
OFF
2
KE-430F, BE-438F
Setting details
Upper thread tension tightening at the sewing start
ON: Enabled
OFF: Disabled
Upper thread tension change (tightening) angle offset at the
sewing start
Upper thread tension release angle offset at the sewing end
Upper thread tension value (tightening) at the sewing start
Upper thread tension value (release) at the sewing start
Thread trimmer solenoid ON timing
Thread trimmer solenoid ON time
Thread trimmer solenoid holding force
Specified final speed output angle offset
Last stitch sewing speed for upper shaft motor
Speed change delay until thread nipper operation is complete
* If the thread nipper device is not to operate, set to "0".
Needle up stop signal output angle offset
Setting details
Error release method when operation has stopped
0: Press the RESET key on the operation panel.
1: Press the STOP switch (available by special order).
2: Press the external input switch (EXIN2).
Needle stop position when sewing is interrupted by the STOP
switch (available by special order)
ON: Needle stops in the up position.
OFF: Needle stops in the down position.
Thread trimming operation when sewing is paused
ON: Thread trimming is not carried out when the pause is
canceled.
OFF: Thread trimming is carried out when the pause is
canceled.
Use of STOP switch (available by special order)
ON: Used
OFF: Not used
Disables needle up stop position monitoring.
ON: Disabled
OFF: Enabled (If the needle up stop position is incorrect, "UP"
will be displayed.)
Time from error occurring to buzzer stopping
OFF: Buzzer does not stop.
2 – 30: Buzzer stops after the specified time.