4. FUNCTION SETTINGS
No.
Setting range
1 − 999,
407
C01 − C30
1 − 999,
408
C01 − C30
1 − 999,
409
C01 − C30
1 − 999,
410
C01 − C30
451
ON/OFF
0.0 − 40.0
460
(mm)
0.0 − 30.0
461
(mm)
0 − 8
462
463
ON/OFF
1 − 3
465
469
ON/OFF
470
ON/OFF
430F: 10 − 17
(mm)
471
438F: 6 − 13
(mm)
16
Initial value
Setting units
1
-
2
-
3
-
4
-
OFF
-
430F: 40.0
0.1
438F: 6.4
430F: 40.0
0.1
438F: 6.4
0
1
OFF
-
1
1
OFF
-
OFF
-
14
1
10
KE-430F, BE-438F
Setting details
Program No. assigned to the F1 key
* Enabled when No. 406 is set to "3".
Program No. assigned to the F2 key
* Enabled when No. 406 is set to "3".
Program No. assigned to the F3 key
* Enabled when No. 406 is set to "3".
Program No. assigned to the F4 key
* Enabled when No. 406 is set to "3".
Split mode selection
ON: Independent split mode
OFF: Continuous split mode
X direction sewing area limitation
Y direction sewing area limitation
Enlargement/reduction reference point
0: Center of sewing frame
1: Sewing start point
2: Center of pattern
3: Front of pattern center
4: Back of pattern center
5: Back-left corner of sewing area
6: Front-left corner of sewing area
7: Back-right corner of sewing area
8: Front-right corner of sewing area
Enlargement/reduction of bar tacking
ON: Bar tacking stitch lengths (pitch less than approx. 1 mm)
are also enlarged or reduced.
OFF: Bar tacking stitch lengths (pitch less than approx. 1 mm)
are not enlarged or reduced.
Setting parallel movement amount for sewing pattern
1: The parallel movement amount for the currently-selected
program can be set in parallel movement mode.
The movement amount is initialized when the power is
turned off and when the program number, pattern number,
X-scale or Y-scale is changed.
2: The parallel movement amount for the currently-selected
program can be set in parallel movement mode.
The movement amount is retained when the power is
turned off, but is initialized when the program number,
pattern number, X-scale or Y-scale is changed.
3: The movement amount can be set for each program using
parameters.
The movement amount is retained when the power is
turned off and when the program number, X-scale or
Y-scale is changed, but is initialized when the pattern
number is changed.
Tension value setting
ON: A common tension value is set for all programs.
* Uniform correction operations are not possible.
OFF: Set separately for each program.
Work clamp/button clamp height setting for each program
ON: Work clamp/button clamp height is set separately for each
program.
OFF: A common work clamp/button clamp height is set for all
programs.
* The work clamp/button clamp height is set by Nos. 471
and 472.
Work clamp/button clamp raise position setting
* Enabled when No. 470 is set to "OFF".