At the start of each work day (or 8 hour shift), an
MHP13/35 / MHP15/44 V3 qual i fied op er a tor must
per form the Daily In spec tion and Main te nance as
listed in the ta ble be low.
The pur pose of the Daily In spec tion and Main te -
nance is to keep the MHP13/35 / MHP15/44 V3 in
proper work ing con di tion and to de tect signs of
mal func tion at the ear li est pos si ble time.
This chap ter shows how to per form the in spec tion
and main te nance re quired for each item in the Daily
In spec tion and Main te nance Ta ble.
Daily Inspection and Maintenance Table
Item
Stabiliser/Boom interlock test
Engine fuel level
Fuel tank cap
Engine oil level
Fuel leaks
Operator's manual
Wiring harnesses
Battery terminals
Battery fluid level
Hydraulic oil level
Hydraulic oil leaks
Tyres and wheels
Bolts and fasteners
Structural damage and welds
Lanyard anchor points
Platform gravity gate
Platform guardrails
Flashing light (option)
Ground control switches
Level sensor (option)
Emergency lower
Platform control box switches
RCD/ELCB AC outlet (option)
Platform work lights (option)
Placards and decals
MHP13/35 & MHP15/44 V3 – 13619-1
7. Daily Inspection and Maintenance
The MHP13/35 / MHP15/44 V3 should be in the
STOWED POSITION and the Mas ter Key Switch
set to OFF be fore you be gin this in spec tion.
De fec tive parts and/or equip ment mal func tions
jeop ar dize the safety of the op er a tor and other per -
son nel, and can cause dam age to the ma chine.
The potential for an accident increases when
operating an MHP that is damaged or
malfunctioning. Death or serious injury can
result from such accidents. Do not operate
an MHP that is damaged or malfunctioning.
Service Required
Perform the test to ensure the system is functioning
Look to see that the fuel tank is full
Check to see that the cap is tight
Check oil level (between dipstick lines)
Visually inspect (hoses and connections)
Check that it is in the holder on the machine
Visually inspect (installation, condition)
Visually inspect (no corrosion)
Check fluid level (1/4" or 6 mm below filler neck)
Visually inspect level (between lines on gauge)
Visually inspect (hoses, tubes)
Visually inspect (condition)
Visually inspect (condition)
Visually inspect (weld cracks, dents)
Visually inspect (condition)
Check condition and operation
Visually inspect (condition)
Visually inspect (operation)
Actuate and inspect for proper operation
Check operation
Check operation (causes correct motion)
Actuate and inspect for proper operation
Check operation
Check operation
Visually inspect (installation, condition)