2. Introduction

AE-200A/AE-50A/AE-200E/AE-50E is a centralized controller.
EW-50A/EW-50E is an LCD-less total management system.
Any connected air conditioning systems can be operated or monitored on the AE-200A/AE-50A/AE-200E/AE-50E's
LCD or the Web browser.
By using a PI controller that is built-in on the AE-200A/AE-50A/EW-50A/AE-200E/AE-50E/EW-50E, the energy-
control-related status can be displayed and Peak Cut control can be performed without a use of a PI controller
(PAC-YG60MCA).
Each AE-200A/AE-50A/AE-200E/AE-50E can control up to a total of 50 indoor units and other equipment. By
connecting AE-200A/AE-200E (main controller) and AE-50A/AE-50E/EW-50A/EW-50E (sub controllers), up to 200
indoor units and other equipment can be controlled.

2-1. Terms used in this manual

- "Centralized Controller AE-200A/AE-200E" is referred to as "AE-200."
- "Centralized Controller AE-50A/AE-50E" is referred to as "AE-50."
- "Centralized Controller EW-50A/EW-50E" is referred to as "EW-50."
- "Booster unit" and "Water HEX unit" are referred to as "Air To Water (PWFY) unit."
- "Advanced HVAC CONTROLLER" is referred to as "AHC."
- "Hot Water Heat Pump unit" is referred to as "HWHP (CAHV, CRHV) unit."

2-2. Required licenses

The required licenses vary, depending on the functions to be used. Refer to the License Classification List for
details. Purchase the required licenses from your dealer. Refer to the Instruction Book (Initial Settings) for how to
register licenses.

2-3. "Group", "Block", and "EM block" definitions

The terms "Group" and "Block" used in this manual are defined as follows.
Group:
Group is a group of air conditioning units and controllers and is the smallest unit that the AE-200/AE-50
can control. The maximum number of units that each group can contain is 16.
Block:
Each block consists of one or more groups. Multiple groups of units in a given block can be monitored
or operated collectively.
EM block: EM block stands for Energy management block, and this groups multiple blocks. Use for charge
apportioning units and for settings of blocks spanning AE-200 and AE-50/EW-50.