Group Icons - Mitsubishi Electric AE-200A Instruction Book

Air conditioning control system centralized controller
Hide thumbs Also See for AE-200A:
Table of Contents

Advertisement

3-1-2. Group icons

Each group icon indicates the operation condition of the group. Touch the icon, and then touch [Operate] to bring up
the operation settings screen.
[1] Air conditioning unit group
ON
*2
Schedule set
Occupied/Vacant
*4 *5 *6
(blue)
(gray)
Note: Besides the 4-way airflow unit icons, 2-way airflow or ceiling-suspended unit icons are also available. Icons can be selected on
the [Groups] screen.
*1 If the LOSSNAY unit is interlocked with the operation of Mr. Slim units, "Interlocked LOSSNAY ON" icon will appear, even when the LOSSNAY
unit is operated individually.
(Applicable M-NET adapter model: PAC-SF48/50/60/70/80/81MA-E)
*2 If any schedule setting is applied to a DIDO controller whose prohibition setting is enabled ([Allow operations] is set to [No operations] on the
[Groups] screen), the "Schedule set" icon will appear, but the scheduled operations will not be performed.
*3 The "Energy-saving ON" icon will appear while the Peak Cut control is performed on the group or on the outdoor unit that is connected to the
group.
*4 The Occupancy/Vacancy status icon will appear only when [
section on the [Unit Info.] screen.
*5 The Occupancy/Vacancy status icon will not appear if the remote controller in the group does not have an occupancy sensor.
*6 The Occupancy/Vacancy status icon takes priority over the "Interlocked LOSSNAY ON" or "Interlocked LOSSNAY OFF" icon.
*7 The Brightness/Darkness status icon will appear only when [
[Brightness] section on the [Unit Info.] screen.
*8 The Brightness/Darkness status icon will not appear if the remote controller in the group does not have a brightness sensor.
*9 The "Setback ON" icon takes priority over the Brightness/Darkness status icon.
*10 The "Starting up" icon will stay when the unit cannot be recognized after startup. Check for proper connection of the air conditioning unit and
proper group settings.
*11 The Hold function can be used on the AE-200A/AE-50A, but not on the AE-200E/AE-50E.
*12 The "Energy-saving ON" icon takes priority over the "Room temperature display" icon.
*13 Whether to show or hide the room temperature can be set in the [Room temperature] section on the [Unit Info.] screen.
[2] LOSSNAY unit (ventilator) group
ON
*1
Energy-saving ON
*1 The "Energy-saving ON" icon will appear while the Peak Cut control is performed on the LOSSNAY unit group.
*2 When the scheduled operations exist during the Night purge operation, the "Night purge ON" icon takes priority over the "Schedule set" icon.
When the scheduled operations exist but are disabled during the Night purge operation, the "Night purge ON" icon takes priority over the
"Schedule disabled" icon.
*3 The "Night purge OFF" icon will appear only on operation setting screens.
WT07992X02
OFF
Energy-saving ON
Schedule disabled
Bright/Dark
Room temperature
*7 *8 *9
(yellow)
(gray)
OFF
Night purge ON/OFF
HOLD ON
ON (Yellow)
Interlocked
Error
LOSSNAY ON
Setback ON
*3 *12
Room humidity
display
*12 *13
(red)
] (blue), [
] (gray), or [
] (yellow), [
] (gray), or [
Error
Schedule set
*2
OFF (Gray) *3
12
Interlocked
*1 *6
LOSSNAY OFF
*9
Starting up
HOLD ON
display
(blue)
] (blue/gray) is selected in the [Occupancy]
] (yellow/gray) is selected in the
*2
Schedule disabled
*6
*10
*11
*2