Operation
A
B
D
Fig. 91:
88
Manual regeneration
The manual regeneration must be started by the operator. This mode is
used for increased soot concentration.
The diesel particulate filter (regeneration required) information symbol
Fig. 91-A appears in the multifunction display.
Use the turn-push knob Fig. 90-69 to switch from the normal view to
the configuration menu and call up the diesel particulate filter menu.
The following conditions must be fulfilled for regeneration:
• The parking brake has been applied
• The engine is switched on and transport mode has been selected
• Temperature > 10 °C
• Regeneration lock has been switched off
If all the conditions have been fulfilled, the symbols Fig. 91-B light up
green. The regeneration can be started. Use the turn-push knob to
select the START symbol Fig. 91-C.
During regeneration, the progress is indicated by a yellow bar. If the
exhaust gas temperatures rise, the diesel particulate filter (hot exhaust
gases) information symbol Fig. 91-D appears. A green bar is displayed
once regeneration has been completed.
Use the turn-push knob to select the EXIT symbol and switch back to
the normal view.
C
Note
For uninterrupted manual regeneration, note the following:
Do not change the speed
Leave the accelerator pedals in neutral position
Do not release the parking brake
Do not use the vehicle during manual regeneration
Non-observance leads to premature termination of
regeneration.