10 Decommissioning

The work described in this section is only to
be performed by personnel qualified for the
assignment accordingly.
DANGER
!
Risk of bursting due to incorrect opening of
pressurized equipment or components.
Valves and pipelines are pressure equipment
that may burst when handled incorrectly.
Flying projectile fragments or the release of
compressed medium can cause serious in-
jury or even death.
Before working on the control valve:
Î Depressurize all plant sections affected
and the valve (including the actuator).
Release any stored energy.
Î Drain the process medium from all the
plant sections concerned as well as the
valve.
WARNING
!
Risk of burn injuries due to hot or cold com-
ponents and pipeline.
Valve components and the pipeline may be-
come very hot or cold. Risk of burn injuries.
Î Allow components and pipelines to cool
down or heat up.
Î Wear protective clothing and safety
gloves.
EB 8020 EN
WARNING
!
Risk of personal injury due to pressurized
components and process medium escaping
under pressure.
Î Do not loosen the screw of the test con-
nection while the valve is pressurized.
WARNING
!
Risk of hearing loss or deafness due to loud
noise.
Noise emission (e.g. cavitation or flashing)
may occur during operation caused by the
process medium and the operating condi-
tions. Additionally, a loud noise may briefly
occur through the sudden venting of the
pneumatic actuator or pneumatic valve ac-
cessories not fitted with noise-reducing fit-
tings. Both can damage hearing.
Î Wear hearing protection when working
near the valve.
WARNING
WARNING
!
!
Crush hazard arising from actuator and
plug stem moving.
Î Do not insert hands or finger into the
yoke while the air supply is connected to
the actuator.
Î Before working on the control valve,
disconnect and lock the pneumatic air
supply as well as the control signal.
Î Do not impede the movement of the actu-
ator and plug stem by inserting objects
into the yoke.
Î Before unblocking the actuator and plug
stem after they have become blocked