Mount the center sensor (P/N 063-0130-018) to the machine's center rack boom tube support using two
1.
1-9/16" W x 2-1/2" L x 3/8" thread U-bolts (P/N 107-0171-611) and four 3/8"-16 zinc flanged lock nuts (P/N
312-1001-164).
Tighten the nuts to ensure the sensor is mounted securely.
2.
Connect the Sensor Cables
Connect left sensor cable (P/N 115-0171-527) to the connector on the outer left sensor.
1.
Route the left sensor cable toward the AutoBoom valve.
2.
Loop and tie-off any excess cable, allowing enough cable for boom folding and extension.
3.
Repeat the steps above to connect the remaining sensor cable(s).
4.
Note:
The sensor cables will be connected to the AutoBoom system in the wiring phase of installation.