Step19
Connect the power cable of the top battery from Step 4 to the terminals of the
cable box. Make sure that red connects to red and black connects to black.
Earthing Point
Figure 31 Earthing Point of Battery
NOTE:
In Australia and New Zealand, please find the earthing point on the right side of the
battery and connect the earthing point of all of the batteries and INV to the ground
refer to AS 3000.
SBP SERIES USER MANUAL
AC-COUPLED BATTERY
STORAGE RETROFIT
Step20
Close the battery covers and connect the PV-MC4 connectors to the system
(connection on both sides). Also, connect all AC cables, the meter communications cable
METER, and the Ethernet cable LAN. Then close the cable box cover.
The installation is now complete.
& INV
Figure 32 PV Wiring
23
24
Step21 Open the front cover of the last battery and remove the DIP cover. Now set the
DIP switch 2 to "on" mode and close the cover again.
1. If there is
only one
4*MC4
Battery
Position
Battery
2. If there are
two or more than two
Battery
Position
Non-bottom
battery
Bottom
battery
NOTE: The DIP setting is only changed on the last battery.
Figure 33 DIP Operation
BAT, the DIP switch of this BAT must be set following:
DIP 1
DIP 2
DIP 3
OFF
ON
OFF
BATs, the DIP switch of the BATs must be set following:
DIP 1
DIP 2
DIP 3
OFF
OFF
OFF
OFF
ON
OFF
INSTALLATION
DIP 4
DIP Switch
OFF
DIP 4
DIP Switch
OFF
OFF

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Smile5

Table of Contents