The set of lift output signals is comprised in two LiftStatusWords. A selector enables the two status words to
be connected to Pad 11 or 12 or to fieldbus S ->M1 or S -> M2.

6.7 Status Word Composition

The set of lift output signals has been composed in two LiftStatusWords, connected respectively to Pad 11
and Pad 12. Possible selections also include the process channels of fieldbus S ->M1 or S -> M2.
Lift Status word 1:
Bit
Description
0
LiftEnable
1
RunCont
2
UpCont
3
DownCont
4
BrakeCont
5
LiftDcBrake
6
Brake2
7
DoorOpen
8
Drive OK
9
SpeedIsZero
10
SpeedRefIsZero Indicates speed reference below the 0 threshold
11
12
13
14
15
Lift Status word 2:
Bit
Description
0
Floor Command Floor call command being executed
1
SelfStudyOn
2
SelfStudyOk
3
StartCycle0
4
ZeroFound
5
PosReady
6
Battery Sel
7
Battery Run
8
RESERVED
9
RESERVED
10
AtFloor
11
PassingBP1
12
PassingBP2
13
UpContMon
14
DownContMon
15
DoorOpenMon
ADL300-EPCv2- User Guide
Remarks
Lift enable command.
Run command contactor
Up command contactor
Down command contactor
Brake command contactor
DC brake function command (firmware)
Brake control signal (See sequences)
Open door command
Indicates drive not in alarm condition
Indicates speed below the 0 threshold
Remarks
Self study command being executed
Self study command OK
Zero cycle command being executed
Zero cycle command OK
Positioning device ready
Battery fwd
Battery rev
Reserved for next stop
Reserved for battery mode run
Lift at floor
Passing Brake Point
Passing Brake Point