gefran ADL300 EPC v2 User Manual page 33

Application: elevator position control sieidrive
Table of Contents

Advertisement

Menu
Par
Description
5.4.10
12024
Actual Multispeed Sel
The currently selected speed is displayed.
0 Multispeed 0
1 fwd/rev speed
2 Zero cycle speed
3 Jog speed
4 Self study speed
5 Battery mode speed
6 Multispeed 6
7 Multispeed 7
8 Null
Menu
Description
Par
5.4.11
12026
Actual Multi spd out
The lift car speed is displayed in m/s.
Menu
Par
Description
5.4.12
12038
Actual Lift State
Lift sequence status display.
05.05 – LIFT COMMANDS
The input commands of the EPC lift application can be connected to a signal via a switch that can be used to
select from among a series of options listed in the selection list.
The selection list can be used to select from among the following options for each single command:
-
Null or One
-
Digital Inputs of the I/O expansion card
-
Some internal signals (e.g. "Brake cont mon" ..)
-
A selectable "LiftDecomp1" bit (e.g. "Lift decom1 B0")
-
A selectable "LiftDecomp2" bit (e.g. "Lift decom2 B0")
-
PAD15
In I/O configuration the commands are connected to digital inputs
In the CANopen configuration they are connected to the LiftDecomp connected in turn for instance via the
variable Control word 2 to a fieldbus process channel e.g. PDC FieldBus M->S2..
The variable Control word 2 can generally be connected to another fieldbus process channel or to the drive
parameter Wcomp or to PAD16.
The default configuration is shown in the table below:
Input
Enable
Floor Call
Cycle 0
ADL300-EPCv2- User Guide
UM
Type
ENUM
UM
Type
m/s
FLOAT
UM
Type
INT
Description
Enable command
Floor call command
Zero cycle command
____________________ _
FB BIT
Def
Min
0
0
FB BIT
Def
Min
0
FB BIT
Def
Min
Enable digital input
Dig input 6X
Dig input 4X
Max
Acc
Mod
8
R
FVS
Max
Acc
Mod
R
FVS
Max
Acc
Mod
R
FVS
Default source
Page 33 of 64