gefran ADL300 EPC v2 User Manual page 11

Application: elevator position control sieidrive
Table of Contents

Advertisement

Layout of floor counter cams
The cams must be arranged as follows with respect to the lift floor:
Sensor A
Cam A
Line of the floor
Positive direction
LC
d1 = d2
z1, z2, z3 >= LC / 2
Landing Zone = (LC / 2) * 3
ADL300-EPCv2- User Guide
Length of cam A and of cam B.
Distance between the lower edge of cam A and the line of the floor.
Distance between the upper edge of cam B and the line of the floor.
Dimension of an acquisition zone.
This value must be greater than or equal to LunghezzaMinimaCamma / 2.
Dimension of the landing zone
____________________ _
Sensor B
d1
LC
d2
Cam B
z1
Landing
z2
Zone
z2
Page 11 of 64