gefran ADL300 EPC v2 User Manual page 34

Application: elevator position control sieidrive
Table of Contents

Advertisement

Self study
Jog Fwd
Jog Rev
Realignment
Forward
Reverse
Stop
Maintenance
Battery Mode
Battery Run
Floor 0
Floor 1
Floor 2
Floor 3
Menu
Par
Description
5.5.1
11002 Emergency mode
0 = Up
1 = Down
2 = Autoselect
If the drive is in the emergency condition and cannot find zero, the parameter tells it which direction to move
in.
Menu
Par
Description
5.5.2
11400
Enable and sel
Setting of the source for the enable command "COMMAND SOURCE LIST":
1110 Mon ing digitale E
1210 Mon ing digitale 1X
1212 Mon ing digitale 2X
1214 Mon ing digitale 3X
1216 Mon ing digitale 4X
1218 Mon ing digitale 5X
1220 Mon ing digitale 6X
1222 Mon ing digitale 7X
1224 Mon ing digitale 8X
1226 Mon ing digitale 9X
1228 Mon ing digitale 10X
1230 Mon ing digitale 11X
1232 Mon ing digitale 12X
16 Mon com contattore
19 Mon contatt discesa
17 Mon com freno
18 Mon porta aperta
3728 PAD15
6000 Zero
6002 One
20 Lift decom B0
21 Lift decom B1
22 Lift decom B2
23 Lift decom B3
24 Lift decom B4
25 Lift decom B5
26 Lift decom B6
27 Lift decom B7
28 Lift decom B8
29 Lift decom B9
30 Lift decom B10
31 Lift decom B11
32 Lift decom B12
33 Lift decom B13
34 Lift decom B14
35 Lift decom B15
ADL300-EPCv2- User Guide
Self study command
Jog forward command
Jog reverse command
Realignment command
Forward command
Reverse command
Stop command
Maintenance command
Battery Mode command
Battery Run command
Floor command bit 0
Floor command bit 1
Floor command bit 2
Floor command bit 3
UM
Type
ENUM
UM
Type
ENUM
____________________ _
Dig input 5X
Dig input 7X
Dig input 8X
Dig input 9X
Null
Null
Null
Null
Dig input 3X
Dig input 3X
Dig input 10X
Dig input 11X
Dig input 12X
Null
FB BIT
Def
Min
0
FB BIT
Def
Min
1110
Max
Acc
Mod
RW
FVS
Max
Acc
Mod
RW
FVS
Page 34 of 64