Par
Description
5.1.13
12050
Inertia Calculated
The system inertia with half load relayed to the motor is displayed. This value can be entered in the Inertia
parameter in the SPEED REG GAINS menu.
05.02 – SPEED
Menu
Description
Par
5.2.1
11022
Multispeed 0
Setting of the value of multispeed 0. This can be selected via digital input, fieldbus, etc.
The value selected is the reference for the lift S ramp.
NB:
This speed cannot be changed. It must always be zero
Menu
Description
Par
5.2.2
11024
Speed fwd / rev
Setting of the value of multispeed 1. The selected value is the reference for the lift S ramp.
The value of this parameter is assumed as forward/reverse speed
Menu
Par
Description
5.2.3
11026
Speed zero Cycle
Setting of the value of multispeed 2. The selected value is the reference for the lift S ramp.
The value of this parameter is assumed as zero cycle speed.
Menu
Description
Par
5.2.4
11028
Speed jog
Setting of the value of multispeed 3. The selected value is the reference for the lift S ramp.
The value of this parameter is assumed as jog speed
Menu
Par
Description
5.2.5
11030
Speed self-study
Setting of the value of multispeed 4. The selected value is the reference for the lift S ramp.
The value of this parameter is assumed as Self Study speed
Menu
Par
Description
5.2.6
11032
Speed Battery Mode
Setting of the value of multispeed 5. The selected value is the reference for the lift S ramp.
The value of this parameter is assumed as battery mode speed.
Menu
Description
Par
5.2.7
11034
Multispeed 6
Setting of the value of multispeed 6. This can be selected via digital input, fieldbus, etc.
The value selected is the reference for the lift S ramp.
Menu
Par
Description
5.2.8
11036
Multispeed 7
Setting of the value of multispeed 7. This can be selected via digital input, fieldbus, etc.
The value selected is the reference for the lift S ramp
Menu
Description
Par
5.2.9
11038
Speed zero Cyc
Setting of the low speed value.
0 Multispeed 0
ADL300-EPCv2- User Guide
UM
Type
Kgm2
FLOAT
UM
Type
m/s
FLOAT
UM
Type
m/s
FLOAT
UM
Type
m/s
FLOAT
UM
Type
m/s
FLOAT
UM
Type
m/s
FLOAT
UM
Type
m/s
FLOAT
UM
Type
m/s
FLOAT
UM
Type
m/s
FLOAT
UM
Type
m/s
ENUM
____________________ _
FB BIT
Def
Min
FB BIT
Def
Min
0.00
0.00
FB BIT
Def
Min
1.00
0.00
FB BIT
Def
Min
0.40
0.00
FB BIT
Def
Min
1.00
0.00
FB BIT
Def
Min
0.40
0.00
FB BIT
Def
Min
0.10
0.00
FB BIT
Def
Min
0.00
0.00
FB BIT
Def
Min
0.00
0.00
FB BIT
Def
Min
2
0
Max
Acc
Mod
R
FVS
Max
Acc
Mod
0.00
RW
FVS
Max
Acc
Mod
10000
RW
FVS
Max
Acc
Mod
10000
RW
FVS
Max
Acc
Mod
10000
RW
FVS
Max
Acc
Mod
10000
RW
FVS
Max
Acc
Mod
10000
RW
FVS
Max
Acc
Mod
10000
RW
FVS
Max
Acc
Mod
10000
RW
FVS
Max
Acc
Mod
8
RW
FVS