05.09 – LIFT ALARMS
The MdPlc application for ADL300 manages and generates the following alarms:
Alarm
Plc1 fault
Plc2 fault
Plc3 fault
Plc4 fault
Plc5 fault
Plc6 fault
Plc7 fault
Plc8 fault
All alarms envisage a parameter used to configure the action performed after the alarm has been activated.
Action: used to set the action to be taken after the alarm has been generated as follows.
Action
Ignore
The alarm is not inserted in the alarm list, it is not inserted in the alarm log, it is not signalled
on the digital outputs, the drive commands are not modified.
Warning
The alarm is inserted in the alarm list, it is inserted in the alarm log, it is signalled on the
digital outputs, the First alarm data is updated, the Alarm active data is updated, the drive
commands are not modified.
Disable
The alarm is inserted in the alarm list, it is inserted in the alarm log, it is signalled on the
digital outputs, the First alarm data is updated, the Alarm active data is updated, the Stop
command is sent and the motor is disabled and stops due to inertia.
Stop
The alarm is inserted in the alarm list, it is inserted in the alarm log, it is signalled on the
digital outputs, the First alarm data is updated, the Alarm active data is updated, the Stop
command is sent. The drive moves to zero speed with the maximum current possible. The
drive is disabled when the Speed 0 delay signal is enabled.
Fast Stop
The alarm is inserted in the alarm list, it is inserted in the alarm log, it is signalled on the digital
outputs, the First alarm data is updated, the Alarm active data is updated, the Stop command
is sent. The drive moves to zero speed with the maximum current possible. The drive is
disabled when the Speed 0 delay signal is enabled.
Lift Stop
The drive moves to zero speed with the set ramp time. The drive is disabled when zero
speed is reached. Once the drive has been disabled the alarm is inserted in the alarm list, it
is signalled to the digital outputs.
Menu
Par
Description
5.9.1
11268
Reset Brake Alarm
This command is a reset of the Brake Alarm.
Procedure to reset:
1. Go to menù 5.9 LIFT ALARMS, check if the Brake Alarm is ON.
2. Go to parameter 11268 Reset Brake Alarm (default 0).
3. The system requires a code, type the code 5313
4. Go to menù 5.9 LIFT ALARMS, check if the Brake Alarm is OFF.
Menu
Par
Description
5.9.2
11560
Floor Alarm Activity
Setting of the behaviour of the drive if the "Floor alarm" is present. This alarm indicates that the correct
sequence for cams A and B cannot be found upon arrival at the floor in case of an internal positioning
device.
0 Ignore
1 Warning
2 Disable
3 Stop
ADL300-EPCv2- User Guide
Type of EPC alarm
Contactor feedback
Brake feedback
Door feedback
Data Base Alarm
Calc Alarm
Speed Limit
Upper down Limit
Floor Alarm
UM
Type
Short
UM
INT16
____________________ _
Contactor feedback signal error
Brake feedback signal error
Door feedback signal error
Restricted
Restricted
Speed limit exceeded
Rephaser alarm
Floor not reached in position
FB BIT
Def
0
to unblock the alarm.
Type
FB BIT
Def
0
Description
Min
Max
***
***
Min
Max
0
5
Page 43 of 64
Acc
Mod
RW
FVS
Acc
Mod
RW
FVS