When set to 0 the contactor sequences can be enabled without sending the Enable command (Enable is
only needed for motor operation). The enable signal can be sent by an auxiliary contact of the output
contactors.
If set to 1 the contactor sequences can only be enabled if the enable command is active.
Menu
Par
Description
5.4.2
11062
Cont Close Delay
Setting of the delay for closing the contactor.
Menu
Description
Par
5.4.3
11064
Brake open delay
Setting of the delay for opening the brake.
Menu
Par
Description
5.4.4
11068
Brake close delay
Setting of the delay for closing the brake.
Menu
Description
Par
5.4.5
11070
Current Ramp Down Delay
Setting of the time needed to reduce the torque from the threshold value active during travel to 0. It defines
the slope of the downward ramp in the "Rampa dimin corrente" function. The purpose of this function is to
prevent immediate removal of motor torque upon application of the brake, which would cause undesirable
stress on the inside of the lift car.
To avoid this phenomenon, after applying the brake the current limits are brought to the current value in use
and then ramped down.
The function is enabled when Current down delay is set to a value other than zero.
This is only possible when Torque curr lim sel (PAR 2354) has a value other than "OFF", otherwise
Current ramp down delay is forced to zero.
Menu
Par
Description
5.4.6
11072
Cont open delay
Setting of the delay for opening the contactor.
Menu
Description
Par
5.4.7
11078
Speed 0 Threshold
Setting of the zero speed threshold, below which the zero speed signal is activated
Menu
Par
Description
5.4.8
11080
Speed 0 Delay
Setting of the zero speed delay. After the zero speed signal and after the delay set in this parameter the zero
speed signal is enabled. These parameters are used to know the lift car stop.
Menu
Par
Description
5.4.9
11086
Door Open Speed
Setting of the door open speed. This function is used to control door opening in advance before the lift car
arrives at the floor. The door open signal can be relayed to a digital output when the speed is below the user-
definable threshold. The function must be enabled from the digital input. The state of execution of the speed
control command for opening the door can be checked by sending the feedback from the door opening
mechanism to the digital input of the drive.
An alarm may be generated if the command and feedback do not coincide.
ADL300-EPCv2- User Guide
UM
Type
ms
INT32
UM
Type
ms
INT32
UM
Type
ms
INT32
UM
Type
ms
INT32
UM
Type
ms
INT32
UM
Type
rpm
INT16
UM
Type
ms
UINT16
UM
Type
m/s
FLOAT
____________________ _
FB BIT
Def
Min
200
FB BIT
Def
Min
200
0
FB BIT
Def
Min
200
0
FB BIT
Def
Min
0
FB BIT
Def
Min
200
0
FB BIT
Def
Min
1
FB BIT
Def
Min
0
0
FB BIT
Def
Min
0.0010
Max
Acc
0
10000
RW
Max
Acc
10000
RW
Max
Acc
10000
RW
Max
Acc
0
10000
RW
Max
Acc
10000
RW
Max
Acc
RW
Max
Acc
10000
RW
Max
Acc
RW
Page 32 of 64
Mod
FVS
Mod
FVS
Mod
FVS
Mod
FVS
Mod
FVS
Mod
FVS
Mod
FVS
Mod
FVS

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sieidrive adl300 epc

Table of Contents