05.06 – INPUTS
The input signals of the EPC lift application can be connected to a signal via a switch that can be used to
select from among a series of options listed in the selection list.
The selection list can be used to select from among the following options for each single input:
-
Null or One
-
Digital Inputs of the I/O expansion card
-
Some internal signals (e.g. "Brake cont mon" ..)
-
A selectable "LiftDecomp1" bit (e.g. "Lift decom1 B0")
-
A selectable "LiftDecomp2" bit (e.g. "Lift decom2 B0")
-
PAD15
In I/O configuration they are connected to digital inputs
In the CANopen configuration they are connected to the LiftDecomp connected in turn for instance via the
variable Control word 1 to a fieldbus process channel e.g. PDC FieldBus M->S1..
The variable Control word 1 can generally be connected to another fieldbus process channel or to the drive
parameter Wcomp or to PAD16.
The default configuration is shown in the table below:
Input
CAM A
CAM B
Input Upper Limit
Input Lower Limit
Input Slow Upper Limit
Input Slow Lower Limit
Input Contactor Feedback
Input Brake Feedback
Input Door Open
Input Door Feedback
(*) CAM A and CAM B must always be selected Null and must always be connected to the freeze
inputs of the encoder expansion card.
Menu
Par
Description
5.6.1
11054
Cam Upper Limit
This parameter allow to define how many floors is positioned the sensor before the upper floor.
Menu
Par
Description
5.6.2
11056
Cam Below Limit
This parameter allow to define how many floors is positioned the sensor before the bottom floor.
Menu
Par
Description
5.6.3
11252
Brake fbk A3 sel
Selection of the alarm Brake out of service. The alarm function is disabled by default.
Selection list for the enabling source:
6000 Null
6002 Uno
12250 BO Lift decomp
12252 B1 Lift decomp
12254 B2 Lift decomp
12256 B3 Lift decomp
12258 B4 Lift decomp
12260 B5 Lift decomp
ADL300-EPCv2- User Guide
Description
Cam A input
Cam B input
Upper limit input
lower limit input
Slow upper limit input
Slow lower limit input
Contactor feedback input
Brake feedback input
Door open input
Door feedback input
UM
Type
ENUM
UM
Type
ENUM
UM
Type
ENUM
____________________ _
Null (*)
Null (*)
Dig input 1X
Dig input 2X
Dig input 1X
Dig input 2X
Run Cont Mon
Brake cont mon
Door Open Mon
Null
FB BIT
Def
Min
1
0
FB BIT
Def
Min
1
1
FB BIT
Def
Min
1
1
Default source
Max
Acc
Mod
4
RW
FVS
Max
Acc
Mod
4
RW
FVS
Max
Acc
Mod
4
RW
FVS
Page 37 of 64

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sieidrive adl300 epc

Table of Contents