gefran ADL300 EPC v2 User Manual page 48

Application: elevator position control sieidrive
Table of Contents

Advertisement

05.12 – FLOOR ARRAY
The Self Study command is used to detect the position of the cams that indicate the position of the floors in
the lift shaft. These positions are detected automatically by performing a series of movements. The following
positions are stored for each floor: A Low, B Low, A High, B High.
The values read in this phase are stored in the parameters contained in this menu.
No direct floor call or movement commands are possible (except jog and zero cycle) unless a Self Study
command has been correctly executed.
Position of cams floors 0 to 31
n
Floor number
#
cam A
Line of the
floor
Positive direction
Menu
Par
Description
5.12.1
11048
Correction Fwd
This allows to compensate the difference between the expected level for the car stop and the level that
the car really stop, when the car go from the bottom to the top.
Menu
Par
Description
5.12.2
11050
Correction Rev
This allows to compensate the difference between the expected level for the car stop and the level that
the car really stop, when the car go from the top to the bottom.
Menu
Par
Descrizione
5.12.3
11066 Floor Selection
This parameter allows the selection of the floor where the edge of the cams will be set (by par. 11074
and 11076).
ADL300-EPCv2- User Guide
B Low
Position of lower edge
of cam B
m
UM
Type
m
FLOAT
UM
Type
m
FLOAT
UM
Tipo
INT
____________________ _
A High
Position of upper edge of
cam A
m
A High
B High
A Low
B Low
cam B
FB BIT
Def
0.0000
FB BIT
Def
0.0000
FB BIT
Def
0
Min
Max
Acc
RW
Min
Max
Acc
RW
Min
Max
Acc
0
31
RW
Page 48 of 64
Mod
FVS
Mod
FVS
Mod
FVS

Advertisement