If set to 0 the brake feedback alarm is signalled immediately.
If set to 1 the possible brake feedback alarm is signalled at the end of the travel: this allows the lift car to
reach the floor in case of a faulty brake status signal.
Menu
Description
Par
5.9.8
11574 Brake hold off
Setting of the delay between the signalling of the Brake Feedback alarm condition and activation of the
alarm. If an alarm condition occurs, the drive will wait for the set time before activating the alarm. If the
alarm is removed within the time set in this parameter, the drive will not activate it.
Menu
Par
Description
5.9.9
11576
Cont hold off
Setting of the delay between the signalling of the Contactor Feedback alarm condition and activation of
the alarm. If an alarm condition occurs, the drive will wait for the set time before activating the alarm. If
the alarm is removed within the time set in this parameter, the drive will not activate it.
Menu
Par
Description
5.9.10
11578
Door Hold off
Setting of the delay between the signalling of the Door Feedback alarm condition and activation of the
alarm. If an alarm condition occurs, the drive will wait for the set time before activating the alarm. If the
alarm is removed within the time set in this parameter, the drive will not activate it.
ADL300-EPCv2- User Guide
UM
Type
ms
INT16
UM
Type
ms
INT16
UM
Type
ms
INT16
____________________ _
FB BIT
Def
Min
1000
FB BIT
Def
Min
1000
FB BIT
Def
Min
1000
Max
Acc
Mod
RW
FVS
Max
Acc
Mod
RW
FVS
Max
Acc
Mod
RW
FVS